Henny Penny OFE- 290 Operation Download Page 16

                       Model OFE- 290

3-15.    SPECIAL PROGRAM MODE

        (Continued)

Factory Presets (F/C, Gas/Electric, Speaker Volume,
Speaker Frequency, Codes, Initialize System)

1.

Press and hold the FUNCTION button for two seconds until
“REG PROGRAM” shows in the display.  As soon as
“REG PROGRAM” shows in the display, press and release
the FUNCTION button 3 times until “FAC PRESET” shows
in the display.

2.

When “CODE” shows on the display, enter 2957.  “DEG”
and “MODE” flashes in the display.  Press any of the product
buttons to toggle from ºF to ºC, and vice versa.

3.

Press and release the FUNCTION button and “TYPE”
and “FRYR” flashes in the display.  Press any of the product
buttons to toggle from “GAS” to “ELEC”, or vice versa.

4.

Press and release the FUNCTION button twice, and
“SPKR” and “VOL” flashes in the display.  The volume can
be changed from 01 to 10, 10 being the loudest.

5.

Press and release the FUNCTION button 3 times, and
“SPKR” and “FREQ” will flash in the display.  The frequency
can be set from 100 to 2000.

6.

Press and release the FUNCTION button 10 times, and
“INITIALIZE SYSTEM” scrolls across the display.  Press
and hold any of the product buttons and the display will count
down from 5.  Once the display counts down, release the
product button, and the control will set factory preset param-
eters into the controls.

Before attempting to change the other modes in the Factory
Preset Mode, please call the Henny Penny Technical Service
Department at 1-800-417-8405, or 1-937-456-8405.

3-16

      703

Summary of Contents for OFE- 290

Page 1: ...todraintheshorteningfromthefrypotintothefilterdrain pan Drain Interlock Switch Amicroswitchthatprovidesprotectionforthefrypotintheeventan operatorinadvertentlydrainstheshorteningfromthefrypotwhile themainswitchisinthePOWERposition theswitchisdesignedto automaticallyshutofftheheatwhenthedrainvalveisopened Shortening Mixing System Ashorteningmixingcapabilitytohelpensureshorteningisproperly mixedtopr...

Page 2: ...to avoidburns FilterUnion Connects the filter to the filter pump and allows easy removal of the filteranddrainpan Fuses Aprotectivedevicewhichbreaksthecircuitwhenthecurrent exceeds the rated value 3 2 LID OPERATION Tocloselid 1 Lower the lid until latch comes into contact with the pot Toopenlid 1 Unlatchthefrontlidlatch 2 Lift up on handle to raise lid 3 3 MELT CYCLE If the shortening is below 185...

Page 3: ...eremainingcooktime during Cook Cycles and also the shortening temperature on demand from the operator Heat Indicator Illuminateswheneverthecontrolcallsforheat whenshortening temperature has been reached the heat light goes off HITemperature Indicator The display reads HI if the shortening temperature is 40 F above thesetpoint DropIndicator The display reads DROP when the shortening has reached the...

Page 4: ...erature thistemperatureextendstheshorteninglifeand minimizesthetimetoheattheshorteningforthenextCookCycle EXIT COOL button must be pressed to heat up to setpoint tem perature ALTHOUGHTHE DISPLAYWILLREAD COOL DURINGTHE STANDBYMODE THE SHORTEN ING IS HOTAND WILLCAUSE BURNS 3 4 SWITCHESAND INDICATORS Continued 3 4 504 TEMPERATURE BUTTON DIGITALDISPLAY Figure 3 2 ...

Page 5: ...rtening be used in the open fryer Some low grade shortenings have a highmoisturecontentandwillcausefoamingandboilingover To avoid severe burns when pouring hot shortening into frypot wear gloves and take care to avoid splashing 2 The electric model requires 100 lbs 45 Kg of shortening The frypot has 2 level indicator lines inscribed on the rear wallofthefrypotwhichshowwhentheheatedshorteningisat t...

Page 6: ...KG IS THE MAXIMUM AMOUNTOFPRODUCTPER FRYPOT FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RE SULT IN SHORTENINGOVERFLOWINGTHE FRYPOTWHICH COULD CAUSE SERIOUS BURNS PERSONALINJURY FIREAND OR PROPERTYDAMAGE 2 Turn the POWER PUMP switch to the POWER position and press the appropriate product button to select the amount of product to be cooked 3 Stir the shortening as it s heating up from a cold start Be s...

Page 7: ... on the lid starting with the bottom rack to prevent damaged product Before loading product onto the racks lower the racks into the hot shortening to prevent the product sticking to the racks 6 Lower and latch the lid down and press the appropriate product button 7 At the end of the cycle an alarm sounds and the display shows DONE At this time press the appropriate product button 8 Unlatchandraise...

Page 8: ... 9 5 kgs maximum orplaceproduct withextrememoisturecontent into racks WITH PROLONGED USE THE FLASHPOINT OF SHORTENING IS REDUCED DISCARD SHORT ENING IF IT SHOWS SIGNS OF EXCESSIVE SMOKING OR FOAMING SERIOUS BURNS PERSONALINJURY FIRE AND OR PROPERTY DAMAGE COULD RESULT 3 8 FILTERING The Henny Penny gas 6 head open fryer Model 290 must be INSTRUCTIONS cleaned and the shortening must be cleaned and p...

Page 9: ...instructions causes splashing of shortening and could result in personal injury Surfaces of fryer and racks will be hot Use care when filtering to avoid getting burned 3 Remove cooking racks carrier and wipe bottom of lid Tilt lid out of the way to clean frypot 4 Pull drain handle towards you to open drain valve The handle should point straight out to the front of the fryer Use large white brush t...

Page 10: ...HE SHORTENING IT S POSSIBLE THATTHE FILTER CONNECTIONATTHE UNION ON THE FILTER TUBE IS NOTTIGHTENED PROPERLY IFSO TURN OFFTHE PUMPAND USE PROTECTIVE CLOTH OR GLOVE WHEN TIGHTENING THE UNION THIS UNION WILLBE HOTAND SEVERE BURNS WILLRESULT 3 9 CHANGINGTHE FILTER The filter envelope should be changed after 10 12 filterings or ENVELOPE whenever it becomes clogged with crumbs Refer to KFC s Standards ...

Page 11: ...t in the frypot it must be drained by slowly pulling the drain handle out towards you 3 Close the drain valve and discard the shortening 4 Raise lid remove the racks and carrier from lid and tilt lid back so that the lid won t interfere with cleaning 5 Refer to KFC s Standard s Library on cleaning instructions If the cleaning solution in the frypot starts to foam and boil over immediately turn the...

Page 12: ...e following paragraphs provide step by step preventive maintenance procedures to be performed by the operator Procedure Frequency Filteringofshortening See KFC s Standards Library Changingofshortening See KFC s Standards Library Changingthefilterenvelope See KFC s Standards Library Cleaningthefrypot See KFC s Standards Library CleaningNylattrons Monthly seebelow Lubricatelidrollers Annually seebel...

Page 13: ...Cycle and can be changed by pressing the appropriate numbers Ex Press 1 0 0 0 and 10 00 flashes on the right side of the display settingthestarttimeat10minutes 5 After setting the time press and release the FUNCTION button and INT1 and TEMP flashes on the left side of the display The right side shows the starting temperature and can be changed by pressing the appropriate numbers Ex Press 2 5 0 and...

Page 14: ...an be toggled by pressing any of the product buttons l 0 YES means the alarm tone automatically stops after several beeps NO means some one must manually press the appropriate product button to stop the alarm tone 10 Repeat steps 9 and 10 for alarms 2 and 3 11 After alarm 3 is set press and release the FUNCTION button FILTER and CYCLES show on the left side of the display and the Filter Cycle valu...

Page 15: ...ed 14 To program second interval press and release the SCAN button while in theTime Mode of the first mode INT2 and TIME willflashontheleftsideofthedisplay Then follow the steps above starting with step 4 3 15 SPECIAL PROGRAM MODE Review Usage 1 Press and hold the FUNCTION button for two seconds until REG PROGRAM shows in the display As soon as REG PROGRAM shows in the display press and release th...

Page 16: ...e product buttons to toggle from GAS to ELEC or vice versa 4 Press and release the FUNCTION button twice and SPKR and VOL flashesinthedisplay Thevolumecan be changed from 01 to 10 10 being the loudest 5 Press and release the FUNCTION button 3 times and SPKR and FREQ willflashinthedisplay Thefrequency can be set from 100 to 2000 6 Press and release the FUNCTION button 10 times and INITIALIZE SYSTEM...

Page 17: ...splay Also the LEDs over 1 and 3 flashes alternately 3 To test the heat circuit press and hold the 1 button 4 To test the pump system press and hold the 3 button Appliance Test Press and hold the FUNCTION button for two seconds until REG PROGRAM shows in the display As soon as REG PROGRAM shows in the display press and release the FUNCTION button 5 times until APPL TEST shows inthedisplay Withthep...

Page 18: ... Press and release the FUNCTION button twice and MELT ON TIME and 100s shows alternately in thedisplay alongwiththelengthoftimetheheatison This should be set at 1700 and should not be changed until the factoryisconsulted 5 Press and release the FUNCTION button three times and COOL SET and POINT shows alternately in the display alongwiththetemperatureatwhichthecontrolexits the melt cycle This is se...

Reviews: