![Henny Penny HHC-990 Troubleshooting Download Page 4](http://html1.mh-extra.com/html/henny-penny/hhc-990/hhc-990_troubleshooting_2124254004.webp)
Model HHC-990
5-2. ERROR CODES AND
WARNINGS (Continued)
“E-41 SYSTEM DATA LOST”
• Memory scrambled
“E-46 DATA SAVE FAILED”
• Memory scrambled
“E-80 VENT STUCK OR
•
Vent on rear of module
BAD SWITCH”
stuck or faulty vent
activation switch
“PLEASE DE-LIME
• Water pan needs
WATER PAN”
cleaned
“WATER LEVEL LOW, PLEASE”
•
Water pan low on water
or empty
303
4-8
• Turn switch to OFF position, then back to
ON; if the display shows “E-41”, the
control should be re-initialized (see Pro-
gramming Section); if “E-41”persists, have
PC board replaced
• Turn switch to OFF position, then back to
ON; if the display shows “E-46”, the
control should be re-initialized (see Pro-
gramming Section); if “E-46”persists, have
PC board replaced
• Check vent on rear of module for obstruc-
tions, or have vent activation switch
replaced
• Follow the weekly cleaning procedures;
this warning will not shut down the heat
or humidity; if “PLEASE DE-LIME
WATER PAN” persists, have PC board
replaced
• Fill water pan, in bottom of unit, to the
maximum water fill mark; this warning
won’t shut down the heat or humidity
Display
Cause
Panel Board Correction