Henny Penny HHC-990 Troubleshooting Download Page 2

Model HHC-990

303

           4-7

5-2.    ERROR CODES AND

The display shows the following error codes and warnings when a

            WARNINGS

fault is detected, along with an alarm sound.  Both the heat and
humidity systems shut down, except when specified otherwise.

Display

Cause

Panel Board Correction

“E-4

CPU TOO HOT”

•  Control board too hot;

unit overheating or
louvers clogged

“E-5

AIR TEMP TOO HOT”

•  Faulty relay, PC board,

or air probe

“E-54A CPU TEMP SENSOR

•  Faulty PC board

OPEN”

“E-54B CPU TEMP SENSOR

•  Faulty PC board

SHORTED”

“E-6A

AIR TEMP SENSOR

•  Faulty air probe

FAILED OPEN”

• Turn switch to OFF position, then back to

ON;  if display still shows “E-4”, the PC
board is getting too hot;  clean louvers and
check cooling fan; if cooling fan is not
working, have it replaced; once panel
cools down, the controls should return to
normal;  if “E-4” persists, have the PC
board replaced

• Turn switch to OFF position, then back to

ON;  if display shows “E-5”, the heating
circuits and temperature probe should be
checked;  once the unit cools down, the
controls should return to normal;  if “E-5”
persists, have the PC board replaced

• Turn switch to OFF position, then back to

ON;  if display shows “E-54A”, the
control should be re-initialized (see Pro-
gramming Section);  if the error code
persists, have PC board replaced

• Turn switch to OFF position, then back to

ON;  if display shows “E-54B”, the
control should be re-initialized (see Pro-
gramming Section);  if the error code
persists, have PC board replaced

• Turn switch to OFF position, then back to

ON;  if the display shows “E-6”, the
temperature probe should be checked;
once the temperature probe is repaired, or
replaced, the controls should return to
normal; if “E-6” persists, have the PC
board replaced