Model
HHC-901/904
3-6. OPERATING
CONTROLS -
COUNTDOWN TIMERS
(if applicable)
(Continued)
Relay Type
7. Press PROGRAM button and “relay type” shows in display.
8. Press buttons to choose “mech” (mechanical relay) or
“SSR” (solid state relay). Set the HHC-901 & 904 controls to
“SSR”.
Off-Set Calibration
9. Press PROGRAM button and “offset calibrate” shows in
display.
10. Press buttons to calibrate the probe tempe 10
degrees. The displayed temperature can be set to match the
actual interior temperature.
CPU Temperature
11. Press PROGRAM button and “therm temp” shows in
display, along with the temperature of the PC board.
Outputs Test
12. Press PROGRAM button and “outputs Test” shows in display.
13. Press buttons to turn on and off the heat outputs to help
in troubleshooting problems.
Initialize System
14. Press PROGRAM button and “init system” shows in display
15. Press and hold either button.
16. The control beeps and the display counts down, “In-3”,
“In-2”, “In-1”.
17. When display reaches “0”, release the button and the
initialization is complete and sets controls to default settings.
If the button is released before “0” is displayed, the
control will not initialize.
10. Press the PROGRAM button to return to the Fahrenheit/Cel-
sius mode, or press and hold the PROGRAM button to exit
programming.
3-8
Aug. 2009