3-6.  OPERATING 

        CONTROLS -

        COUNTDOWN TIMERS

        (if applicable)

        (Continued)

Relay Type

7.    Press PROGRAM button and “relay type” shows in display.

8.  Press     buttons to choose “mech” (mechanical relay) or 

    “SSR” (solid state relay).  Set the HHC-901 & 904 controls to 

“SSR”.

Off-Set Calibration

9.    Press PROGRAM button and “offset calibrate” shows in 

   display.

10.  Press     buttons to calibrate the probe tempe 10  

    degrees.  The displayed temperature can be set to match the 

    actual interior temperature.

CPU Temperature

11.   Press PROGRAM button and “therm temp” shows in 

    display, along with the temperature of the PC board.

Outputs Test

12.  Press PROGRAM button and “outputs Test” shows in display.

13.  Press     buttons to turn on and off the heat outputs to help 

    in troubleshooting problems.

 Initialize  System

14.  Press PROGRAM button and “init system” shows in display

 15.  Press and hold either   button.

16.  The control beeps and the display counts down, “In-3”, 

    “In-2”, “In-1”.

17.  When display reaches “0”, release the button and the 

    initialization is complete and sets controls to default settings.

    If the   button is released before “0” is displayed, the 

    control will not initialize.

10.  Press the PROGRAM button to return to the Fahrenheit/Cel-

sius mode, or press and hold the PROGRAM button to exit 

programming.

3-8 

  Aug. 2009

Summary of Contents for HHC-901

Page 1: ...OPERATOR S M A N U A L REGISTER WARRANTY ONLINE AT WWW HENNYPENNY COM HEATED HOLDING CABINET MODEL HHC 901 HHC 904 ...

Page 2: ......

Page 3: ... Electrical Connection 2 2 2 5 Cabinet Dimensions 2 3 Section 3 OPERATION 3 1 3 1 Introduction 3 1 3 2 Operating Controls 3 1 3 3 Start Up 3 3 3 4 Operation with Product 3 3 3 5 Cleaning Procedures 3 4 3 6 Operating Controls Countdown Timers if applicable 3 5 3 7 SimpleHold Controls if applicable 3 9 Section 4 TROUBLESHOOTING 4 1 4 1 Troubleshooting Guide 4 1 4 2 Error Codes Countdown Timers 4 2 G...

Page 4: ......

Page 5: ...products have been evaluated to the WEEE directive We have also reviewed our products to determine if they comply with the Restriction of Hazardous Substances directive RoHS and have redesigned our products as needed in order to comply To continue compliance with these directives this unit must not be disposed as unsorted municipal waste For proper disposal please contact your nearest Henny Penny ...

Page 6: ...the proper installation operation and maintenance procedures The instructions in this manual have been prepared to aid you in learning the proper pro cedures Where information is of particular importance or is safety related the words NOTICE CAUTION or WARNING are used Their usage is described below SAFETY ALERT SYMBOL is used with DANGER WARNING or CAUTION which indicates a personal injury type h...

Page 7: ...ide the cabinet are secured with cardboard packing The unit is then packed inside a heavy cardboard carton with sufficient padding to withstand normal shipping treatment Any shipping damages should be noted in the presence of the delivery agent and signed prior to his or her departure To remove the Henny Penny Heated Holding Cabinet from the carton you should 1 Carefully cut banding straps 2 Lift ...

Page 8: ...a separate electrical line protected by a fuse or circuit breaker of the proper rating For European markets verify the electrical plug meets the proper electrical rating and country type See local authorities for proper standards To avoid electrical shock the cabinet must be adequately and safely grounded earthed according to local electrical codes FOR EQUIPMENT WITH CE MARK ONLY To prevent electr...

Page 9: ... Model HHC 901 904 2 5 CABINET DIMENSIONS Model HHC 904 Model HHC 901 Aug 2009 2 3 ...

Page 10: ......

Page 11: ...tion Sections should be read and all instructions should be followed before operating the cabinet 3 2 OPERATING CONTROLS Below are the 3 different controls available on the HHC 901 904 units and the description of the items are on the following pages Aug 2009 3 1 Figure 1 13 CDT Figure 3 4 6 CDT Figure 3 5 Simple Controls 10 11 12 4 9 1 2 1 2 3 4 5 6 7 8 9 3 4 5 9 6 7 8 ...

Page 12: ...e program modes and to change the settings 1 2 5 Program Button Press to access the program modes 1 2 6 Heat LED Illuminates when heat is on 1 2 7 Temperature LED Fashes when programming temperature 1 2 8 Timer LED Flashes when programming timers 1 2 3 9 Power Switch A rocker switch that controls electrical current to the unit 3 10 Set Button Press to access the program modes 3 11 Heat Indicator A...

Page 13: ... in as far as it will go so that it does not block air to the temperature probe This will ensure proper operation of these components 3 When the heat indicator goes out or flashes Simple Controls the unit is ready for operation Default temperature is 180o F 82o C The unit should take approximately 25 35 minutes to heat to temperature during start up Be sure that the heat indicator goes out before ...

Page 14: ...e doors and remove all trays from the cabinet 4 Take the trays to a sink and clean them thoroughly 5 Discard all warped or bent pans Failure to discard warped and or bent pans may result in metal shavings dust contaminating food products 6 Remove the water pan and clean it with a soft cloth soap and water 7 Wipe the control panel with a damp cloth Do not splash water around the controls 8 Clean th...

Page 15: ...r cancelled and not affect the status of the other timers 1 Press the desired timer button 2 The time remaining shows in the display For units with front and rear timers the corresponding numbered timer shows on both sides 3 At end of time cycle an alarm sounds and 0 00 is displayed 4 Press the timer to stop alarm and is displayed Press and hold an active timer to cancel Temperature Regulation 1 P...

Page 16: ...LED flashes Several timers can be on at the same time 6 Press buttons to change the starting time 7 Press the timer button to set the new starting time If desired now press another timer button to change its start ing time 8 When finished setting timers press and hold the PRO GRAM button to exit programming Press and hold the PROGRAM button to exit the program mode at any time or if no buttons are...

Page 17: ...it or Celsius 1 Press and hold the PROGRAM button for 4 seconds 2 SetuP and tech are displayed 3 Press 8 timer button for 13 timer units or press 2 timer button for 6 timer units Ex 4 Enter access code 1 2 3 5 temp units and o F is displayed 6 Press buttons to choose between o F Fahrenheit or o C Celsius To exit Special Program mode at any time press and hold the PROGRAM button CE and internationa...

Page 18: ...emp shows in display along with the temperature of the PC board Outputs Test 12 Press PROGRAM button and outputs Test shows in display 13 Press buttons to turn on and off the heat outputs to help in troubleshooting problems Initialize System 14 Press PROGRAM button and init system shows in display 15 Press and hold either button 16 The control beeps and the display counts down In 3 In 2 In 1 17 Wh...

Page 19: ...8405 or 1 937 456 8405 PROGRAMMING Temperature Regulation To change the setpoint temperature press and hold and then use to set the desired setpoint temperature If the controls are locked the setpoint cannot be changed until the controls are unlocked See Special Programming below Special Program Mode Fahrenheit or Celsius With the Power Switch OFF press and hold and then turn the power switch on 1...

Page 20: ...ss and release twice and Cal shows in the display followed by the current probe temperature The probe can be calibrated 10º F and can be changed by using Outputs Test 4 After entering the Special Program Mode press and release three times and OP shows in the display Use to toggle between 888 and a blank display 888 turns all heat outputs on and a blank display turns them off Lock Unlock Controls 5...

Page 21: ... Hold product for recommended soggy time Product dry No water in pan Remove pan and add approximately 1 of hot water Unit will Display not indicating Check probe calibration and not heat to true temperature change calibration or offset desired if necessary temperature Doors being left open too Only open doors as necessary much Gasket torn or worn Replace gasket Both blowers Faulty fuse if unit is ...

Page 22: ...nit cools down the controls should return to normal if E 5 reappears replace control board E 6 Temperature probe failure Turn switch to OFF position then back to ON if E 6 reappears the temperature probe should be checked once the temperature probe is repaired or replaced the controls should return to normal if E 6 reappears replace control board E 41 Programming failure Turn switch to OFF positio...

Page 23: ...product communicates the temperature of the product to the control panel food probe receptacle the connection where the food probe is inserted in order to communicate with the control panel humidity sensor a device that measures the percentage of humidity inside the cabinet during use humidity setting a preset moisture level at which the cabinet operates this setting is programmed at the factory b...

Page 24: ...e cabinet will heat this setting is programmed at the factory but can be changed in the field vent activation switch an automatic control that opens and closes the vent on the rear of the cabinet to maintain the preset humidity level vented panels openings on the cabinet that allow air access on the sides and rear of the module water fill line the line marked on the inside of the water pan that sh...

Page 25: ......

Page 26: ...Penny Corporation P O Box 60 Eaton OH 45320 1 937 456 8400 1 937 456 8402 Fax Toll free in USA 1 800 417 8417 1 800 417 8434 Fax www hennypenny com FM05 059 D Henny Penny Corp Eaton Ohio 45320 Revised 8 4 17 ...

Reviews: