
Error messages
63
Service instructions
10.12.2 Troubleshooting
Ensure customer-supplied water supply on the soft water connection
of unit. The supply pressure on the water connection must be at least
2 bar. If the fault occurs sporadically, check the on-site water
pressure while observing nearby water consumers.
10.13 Failure to access external EEPROM (SOF_ID12)
10.13.1 Description
It is not possible to access the digital key (EEPROM).
10.13.2 Troubleshooting
Make sure that the digital key is oriented correctly and inserted
fully. The side with the hole must point to the sensor connections.
Control board defective.
Digital key defective.
10.14 Faulty CAN connection
10.14.1 Description
There is a communication fault between the operating panel and
control panel. In addition, temperature sensor and fan fault messages
appear on the touchscreen.
10.14.2 Troubleshooting
Replace communication cable between operating panel and
control panel circuit board.
Replace control board.
Replace operating panel.
FM06-078A
Summary of Contents for FSDE 610.610
Page 6: ...Directory of contents 6 Service instructions FM06 078A...
Page 64: ...Error messages 64 Service instructions FM06 078A...
Page 65: ......
Page 66: ......
Page 67: ......