Electric
Space$aver
™
Errors
70
Space$aver
™
Resetting (initializing) the
control electronics
Program running errors (e.g. specified settings were not kept);
can be corrected by resetting (initializing) the electronic
controls. This resets the electronics to the start mode. The
stored program will not be deleted.
To reset the system, press and hold the On/Off button (with the
appliance switched on) for approx. 8 seconds until the control
electronics turn off.
The electronics will switch back on after approx. 10 seconds.
The appliance is now in the start mode (standby) and the
following appears in the start screen display
Measuring mode
If when resetting the control electronics the
"on/off" button is accidentally pressed for longer than 8 sec.
with the appliance switched off, the electronics change into the
measuring mode.
To deactivate the measuring mode again, the "on/off" button
must be pressed for 20 sec. with the appliance switched off.
Then the control electronics change to the normal operating
mode again.
22.01.03 08:07
Menu
∆
T/SRH
Summary of Contents for ECS-605
Page 2: ......
Page 4: ......
Page 10: ...Operating Manual Contents 10 ...
Page 12: ...Electric Space aver 12 Space aver Appliance description ...
Page 29: ...Operation Electric Space aver 29 Space aver ...
Page 30: ...Electric Space aver Operation 30 Space aver ...
Page 50: ...Electric Space aver 50 Additional functions Space aver 50 ...
Page 51: ...Electric Space aver 51 Additional functions Space aver ...
Page 52: ...Electric Space aver More functions 52 Space aver ...
Page 60: ...Electric Space aver Practical tips 60 Space aver ...
Page 73: ......