![Henny Penny AHC-990 Technical Manual Download Page 7](http://html1.mh-extra.com/html/henny-penny/ahc-990/ahc-990_technical-manual_2124124007.webp)
Model AHC-990/993
1-3
OPERATION (Continued)
C. Product dry
• Bad float switch
• Replace float switch
• Bad water heater high limit
• Replace high limit
• Bad water heater
• Check heater and replace if bad;
see Tech Mode item 18
• Humidity setpoint too low
• Increase humidity setpoint
(SP-4) in Special Program Mode
• No water in pan
• Turn water supply on
• Adjust flow control valve
• Check solenoid valve and relay
• Vent stuck open (“E-80”)
• Bad vent motor - replace; see
Tech Mode item 18
• Bad vent motor relay - replace
• Check alignment and condition
of mechanical vent parts
HEATING SYSTEM
A. Unit not heating
• Bad control board
• Replace control board
• Bad high limit
• Check high limit; replace if bad
• Bad air heater or blower relays
• Replace relay
• Bad air heater
• Check heaters and replace if bad;
see Tech Mode item 18
• Faulty wiring
• Check for loose connections or
broken wires
B. Unit not reaching set
• Blower not working.
• Check Blower and replace if bad;
temperature
see Tech Mode item 18
• Bad air heater
• Check heaters and replace if bad;
see Tech Mode item 18
• Bad air heater, or blower relays
• Replace relay
• Doors left open
• Keep doors closed except
to load and serve product
• Door gasket torn or worn
• Replace bad door gaskets
1-3. TROUBLESHOOTING (continued)
Problem
Cause
Correction
Feb. 2011
Summary of Contents for AHC-990
Page 2: ......
Page 3: ......
Page 49: ...Model AHC 990 993 3 27 Feb 2011 ...
Page 52: ...Model AHC 990 993 3 30 March 2011 ...
Page 65: ......