Model AHC-990/993
1-7
1-4. ERROR CODES AND
WARNINGS (Continued)
“E-46 DATA SAVE FAILED”
• Memory scrambled
“E-80 VENT STUCK OR
•
Vent on rear of module
BAD SWITCH”
stuck or faulty vent
activation switch
“WATER LEVEL LOW,
•
Water pan low on
PLEASE ADD WATER”
water or empty
(Appears only if fill option is
set to Manual)
“WATER PAN NOT FILLING,
•
Water supply turned
CHECK WATER SUPPLY”
off
(Appears only if fill option is
set to Auto)
•
Water flow reduced
•
Fill solenoid relay bad
•
Fill solenoid bad
“CALL SERVICE, WATER
• Faulty relay or heater
HEATER FAILURE”
• Turn switch to OFF position, then back
to ON; if the display shows “E-46”, the
control should be re-initialized (see Pro-
gramming Section); if “E-46”persists,
have PC board replaced
• Check vent on rear of module for
obstructions, or have vent activation
switch replaced
• Vent acorn nuts too tight; loosen if
necessary
• Fill water pan, in bottom of unit, to the
maximum water fill mark; this warning
won’t shut down the heat or humidity
• Turn water supply on
•
Adjust flow control valve
•
Check solenoid relay
•
Check solenoid valve
•
Check heater relay and heater
Display
Cause
Panel Board Correction
March 2014
“PURGE”
Unit is purging humidity
No correcting action needed. If message
continues, contact the Henny Penny Tech
-
nical Support Line at 1-800-417-8405