![HENNING MultiRope Series Operating Manual Download Page 10](http://html1.mh-extra.com/html/henning/multirope-series/multirope-series_operating-manual_2124105010.webp)
©
Copyright 2016 by Henning GmbH & Co. KG
Rev. 2.1 09/2016
10
ii. Apply it by pressing
. After that a countdown will be running
from
to
. At
the current weight of the car
including load will be measured. It goes without saying that at
that moment there must not be anything additional in the cabin or
on the car that does not belong there under normal operation
conditions (tools!), and that there must not stay any person in the
cabin or on the car roof in order not to warp the full load
parameter.
iii. As from now on calibration of the rope-sensor is completed and
in effect.
8. Alarm Limits
Alarm limit: a designation that corresponds to the load limit in the cabin, which – if
exceeded – will change the state of the alarm relay. After changing the state of the
alarm-relay, the corresponding status-LED will be luminating.
Standard Model
CANopen Model
AL-1
(freely programmable load)
Changes its state, if the load limit
adjusted by parameter
is
exceeded.
AL-2
(freely programmable load)
Changes its state, if the load limit
adjusted by parameter
is
exceeded.
AL-3
(freely programmable load)
Changes its state, if the load limit
adjusted by parameter
is
exceeded.
AL-E
(
Empty load
)
Changes its state, if the load falls below
the limit adjusted in parameter
.
AL-F
(Full load)
Changes its state, if the load limit
adjusted in parameter
is
exceeded.
AL-O
(Overload)
Changes its state, if the load limit
adjusted in parameter
is
exceeded.
AL-S
(Slack rope)
Changes its state, if the load falls below
the limit adjusted in parameter
.
AL-d
(
Rope difference
)
Changes its state, if the load of one of
the supporting means differs by the limit
adjusted in paramete
r