• 25
3.
Depress inflation pedal to position 1 to start air-
flow through the hose and into the tank. Maintain a
steady pressure for constant flow.
4.
Watch the rising pressure on the tank gauge and
the gauge on the machine. Machine gauge should
cycle between check and inflation pressures while
tank gauge climbs steadily. As tank pressure reaches
60 PSI, the pressure limiter should stop the airflow
automatically. Both gauges should read 60 PSI ± 5 PSI.
5.
Release inflation pedal. Check manual release
valve function by pressing the button and releasing
pressure from the tank until it reaches 50 PSI.
Disconnect inflation hose, and release air inside tank.
6.
Replace pressure limiter if it fails to cycle properly
during inflation, if it fails to shut air supply off at 60 PSI,
or if it malfunctions in any other way. Do not operate
machine with a faulty pressure limiter.
Robotic Arm Maintenance
A. Grease the robotic arm to maintain smooth rotation.
Grease fittings have been provided at the pivot joints.
B. Check bolt torque periodically at pivot joints. Proper
Torque is 200 ft. lbs.
I
In
ns
st
ta
alllla
at
tiio
on
n I
In
ns
st
tr
ru
uc
ct
tiio
on
ns
s
Proper unit installation is necessary for safe
use and efficient operation. Proper installa-
tion also helps protect the unit from dam-
age and makes service easier. Always place
safety poster and instructions near the unit.
Location
Select a location using the drawings below. The area
should provide the operator with enough space to use
the equipment in a safe manner. The area selected
should be well lit, easy to clean and should be away
from oil, grease, brake lathe chips, etc. Avoid areas
where bystanders and customers may be present.
Workspace Requirements
Air Source
The all-air models require a 14 to 15 CFM air source
at 150 PSI. The air/electric models require a 5 CFM air
source at 150 PSI. The safe operating pressure range
for all models is between 110 PSI and 175 PSI at the
machine.
The unit is furnished with a 1/4" pipe thread male fit-
ting for easy connection. This connection is located on
the right side of the rear of the machine. A 1/4" ID hose
(or pipe) for connection to the machine is satisfactory.
Sufficient air pressure assures good performance.
Electrical Source
Electric models require power from a 15 amp, 120
volt electrical circuit. Refer to the serial tag located on
the lower part of the machine for specific electrical
requirements for the unit. Have a licensed electrical
technician perform any necessary changes to the
power source before plugging in the unit. The electrical
CAUTION
Maintain Bolt Torque
at 200 Ft. lbs.
Grease Fittings
88"
(RC200)
76"
(RC100)
66"
72"