Service Manual — COATS Model IBS 2000 • 3
2000 Balancer
Simplified Block Diagram
Piezo
Fan
Phase Converter or Jumper
AC Power
On/Off
Interlock
Switch (NO)
Closed with
hood down
Encoder
Motor
Main CPU
A
Motor
Controller
Power
Supply
Display
Board
LCD Board
Hood Switch (NO)
Closed with hood down
Manual Start
+12
- 12
+ 5
Interlock switch only on models
produced after 12-22-97.
Note:
Note:
The normal position is when the
magnet is next to the switch.
NC = Normally Closed
NO = Normally Open
D
Direct Drive