Before proceeding with any repair or maintenance operation disconnect the EQ RC32 

Automatic Reservoir SP from the main air supply. 

Malfunction 

Possible Cause 

Corrective 

Pressurized air escapes 

between reservoir housing 

and reservoir lid. 

Reservoir Knob is not 

tightened.  

Tighten the reservoir knob. 

O-ring leaks. 

Grease or renew the O-ring. 

Pressurized air escapes at 

the product connection 4. 

Union nut on the product 

connection 4 not tightened. 

Carefully tighten the union nut. 

Air bubble in the product 

Product reservoir is empty. 

Refill product reservoir (see 

section 4.3).   

Dispensing valve not 

correctly connected or 

defective. 

Check the dispensing valve 

(see instruction manual for 

dispensing valve). 

Product reservoir pressure 

is too high. 

Lower pressure, longer 

dispensing time. 

Too little product. 

Dispensing pressure 

inadequate. 

Increase the dispensing 

pressure on the controller. 

Air supply pressure 

inadequate. 

Increase the air supply 

pressure. 

Malfunction of the 

dispensing valve. 

Check the dispensing valve, 

see operating instructions of 

the dispensing valve. 

No product. 

 

Product reservoir is empty.  

Refill the product reservoir 

(Section 4.3)  

Product reservoir is not 

switched on. 

Set the depressurizing valve to 

      pressurize. 

Reservoir (product 

reservoir) is not active. 

Controller 97102: Press 

Controller 97152: Press  

Controller RC15: Press  

Product reservoir defect. 

Henkel Service. 

Summary of Contents for 2814023

Page 1: ...1 EQ RC32 Automatic Reservoir SP IDH 2814023 Operating Manual...

Page 2: ...ion 5 2 2 Control Panel Front Back of controller 6 3 Technical Data 7 4 Installation 8 4 1 Environmental and Operating Conditions 8 4 2 Connecting the Unit 8 4 3 Filling and Refilling the Product Rese...

Page 3: ...are not observed the manufacturer can assume no responsibility Do not expose the connecting cable to heat oil or sharp edges Make sure the Unit stands stable and secure Use only original equipment re...

Page 4: ...oint product level sensor for process controls Integrated solenoid vent valve 1 6 Field of Application Intended use The Loctite EQ RC32 Automatic Reservoir SP is equipped with a single point low level...

Page 5: ...n connected to a controller 97102 97152 or RC15 the automatic reservoir is automatically pressurized when the controller is switched on and automatically depressurized when the controller is switched...

Page 6: ...ressure ON OFF Switch 2 Tank Pressure Gauge 3 Valve Pressure Relief 4 Reservoir Feedline Fitting 5 Reservoir Locking Knob x 3 6 Reservoir Lid 7 Pneumatic Connection P in 8 Low Level connector XS2 9 Lo...

Page 7: ...bs 4 8 8 Internal control voltages 24VDC Pneumatic Supply Clean dry air not to exceed 116 psi 8bar and filtered with a maximum of 10 micron Pneumatic hose size External dia 6mm Operating Temperature 1...

Page 8: ...nt unnecessary loads on the fitting and to ensure compatibility Keep all fitting tight No direct sunlight no UV light No condensing humidity Avoid direct contact with water 4 2 Connecting the Unit Use...

Page 9: ...d safety devices would become clogged and therefore ineffective Warning Before loosening the reservoir locking knobs 6 the EQ RC32 Automatic Reservoir must be depressurized pressure free When dispensi...

Page 10: ...ighten the reservoir knobs by hand Set the depressurizing valve 1 to ON position pressurize On the controller 97102 switch the reservoir to active with the button On the controller 97152 or RC15 switc...

Page 11: ...to the product feed line 5 Insert the product bottle For small bottles use the bottle holder For 250ml product bottle pay attention to ensure the bottle is aligned with the level sensor 6 Check that t...

Page 12: ...pneumatic supply from the unit Clean the product hose and dispensing valve Recommended maximum idle times for different products are shown below Adhesive Maximum idle time for dispensing Systems Anaer...

Page 13: ...spensing valve not correctly connected or defective Check the dispensing valve see instruction manual for dispensing valve Product reservoir pressure is too high Lower pressure longer dispensing time...

Page 14: ...he feedline hose Remove the product bottle and insert a container with approx 0 5 liter of cleaning agent Put on the reservoir lid 6 and uniformly tighten the reservoir locking knobs 5 Operate the dis...

Page 15: ...bing 360636 2 Tank Cord 2 m 147521 3 inch O D Black PE Teflon Lined feedline Tubing 33 feet length 142646 4 Reservoir Lid O ring 478505 5 Pressure Safety Relief Valve 360462 6 Anti Bubbler Kit 2 Adapt...

Page 16: ...rishable items such as fuses filters lights etc No such claim shall be allowed in respect of products which have been neglected or improperly stored transported handled installed connected operated us...

Page 17: ...T POSSIBLE UNDER APPLICABLE LAWS HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF OR OTHERWISE IN CONNECTION WI...

Page 18: ...Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seou...

Reviews: