Observe the maximum supply pressure of the com-
pressed air supply. Refer to Chapter "10) Technical data"
on page 11.
Remove the used cartridges
Refer to figures
{L}
and
{M}
on page III:
1.
Release the trigger (21) and press the red button (19)
(a) until the plungers have moved to the rear stop.
2.
Release the atomizing air line from the spraying
head (b).
3.
Push out the cartridges from below and remove
upwards (c).
Dispose of the cartridge, mixer and atomizing
air line in accordance with the manufacturer’s
instructions.
No.
Fault
Cause
Remedy
1
Plunger discs cannot en-
ter the cartridge
• Use of cartridges that are not sup-
plied by Henkel
• Cartridge not fully inserted in car-
tridge sleeve
• Incorrect plunger disc
• Check that there is no foreign mat-
ter in the cartridge sleeve.
• Push the cartridge fully down into
the cartridge sleeve.
2
The cartridge cannot be
removed from the dis-
penser
The plunger discs are still in position
inside the cartridge
• Press the red button (19) to fully re-
tract the plunger discs to the back
end-stop (see "Remove the used
cartridges", page 10)
3
Dispensing is interrupted
Compressed-air supply has been in-
terrupted
• Check the compressed-air line
4
Material discharge is in-
terrupted
Material has hardened in the mixer
• Replace the mixer (see "Fix the mi-
xer onto the cartridge", page 9)
5
Spraying procedure is in-
terrupted
Atomizing air supply has been inter-
rupted
• Check the atomizing air line and the
quick connectors (see "Fix the mixer
onto the cartridge", page 9)