2 735 061, Rev. 030798
Operating Instructions tico 735 - Elapsed Timer
page 3/12
Installation
Panel mounting
The instrument can be mounted in a panel with a thickness of up to 12 mm. The cutout should be made based
on the recommended panel opening illustrated in the drawing below.
100
96
48
tico 735
PGM
RST
92
+ 0 .5
45
+ 0
.5
Panel Cutout
Insert the unit in the panel through the cutout. Ensure that the panel gasket is not distorted and the instrument is
positioned squarely against the panel. Slide the mounting clamp into place on the instrument and push it
forward until it is firmly in contact with the rear face of the mounting panel and the tabs on the bracket arm are
seated in the mounting grooves on the side of the unit.
The electronic components of the instrument can be removed from the housing after installation without
disconnecting the wiring. To remove the components, grip the side edges of the panel and pull the instrument
forward. Take note of orientation of the unit for subsequent replacement in the housing.