![Hengstler AX65 Installation Instructions Manual Download Page 16](http://html1.mh-extra.com/html/hengstler/ax65/ax65_installation-instructions-manual_2123909016.webp)
16 of 22
Item number: 2-569-013, Version: 3 200116TK
3.1. Components of the encoder
Figure 1: Components encoder
Cap
Terminal box
Fixing screws for terminal box
O-ring
Housing
Grounding screw
3.2. Disassembly / assembly of the terminal box
Loosen the fixing screws to open the terminal box.
Before closing the encoder Loctite 243 (each about 6 mm³) is to be applied onto the two top turns of
the thread of the threaded hole of the cap. For closing the encoder put on the terminal box to the cap.
Tighten up both screws within the curing of the adhesive to a torque of 4 Nm.
Warning!
O-ring between cap and terminal box must not be damaged.
Warning!
Use only the supplied fixing screws with mounted securing ring (specific screw
caps according to EN 60079-0).
Terminal box must be continuously closed without gap to the cap.
EN
Maximum accuracy and durability of our shaft encoders are only guaranteed when using suitable
couplings.
The encoder must not be used in magnetic fields with more than 15mT parallel to the rotation axis of
the shaft and vertical 4mT to the rotation axis of the shaft. This can lead to problems, especially in
multi-turn.