background image

 

 

 

2.9.2  Sauna heaters safety clearances 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 
 

 

 

 

 

 
 
 

Image 3 Safety clearances 

 

 
 
 
 
 
 
 
 
 
 

 

Table. 1  Safety clearances 

 

Effect 

 

kW 

Heater connection cable

 H07RN –F/ 60245 IEC 66

 

mm² 

400V - 415V 3N~ 

Fuse 

4,5 

5 x 1,5 

3 x 10 

6,0 

5 x 1,5 

3 x 10 

8,0 

5 x 2,5 

3 x 16 

9,0 

5 x 2,5 

3 x 16 

 

Table. 2   Heater connection cable and fuse 

 
 

Effect Sauna 

room 

Heaters minimum clearance (mm)

 

Stone 

 
 
 
 
 
 
  kW 

Volume Height 

 

Side 

wall 

 
 

mm 

 

In front of 

 
 
 

mm 

To ceiling 

 

 

mm 

To the 

floor 

 
 

mm 

 
 
 
 

mm 

 

 
 

mm 

 

min.       max. 

Approx     Approx

kg           kg 

min. 

m³ 

max. 

m³ 

 

min. mm 

4,5 3  6  1900  40 

80 

1100  120 135 

245  20  28 

6,0 5  9  1900  45  100 

1100  120 140 

245  20  35 

8,0 8 12  1900  75  130 

1100  150 170 

275  20  35 

9,0 9 13  1900  80  150 

1100  150 175 

275  20  35 

   J

    

     1

50

   280       B

Product Manual    

Havanna STS

 

      Drill. Ø3,5 mm 

Screw 6 x 40 (2 kpl) 
Screw 6 x 16 (2 kpl) 

(mm)

min
30

min
20

min
20

K

A        475       A

min

30

50

5   

   

   

   

    

m

in 

11

00

m

in

 1

900

300     D

(mm)

Minimum distances for the 
mounting bracket (mm) 

Summary of Contents for Havanna STS

Page 1: ...ELECTRIC SAUNA HEATER 400V 415V 3N 1714 45 171817 1714 60 171817 1714 80 171817 1714 90 171817 314 SKSO 76 3 B GENUINE SAUNA STEAM Product Manual Havanna STS...

Page 2: ...8 Preparing for sauna heater installation 7 2 9 Installation 7 2 9 1 Installation instructions 8 2 9 2 Sauna heaters safety clearances 9 2 10 Main connection 10 2 11 Electric heating toggle 10 2 12 L...

Page 3: ...ing the knob at 6 the sauna heater will turn on after six hours and stay warm for four hours unless the timer is turned to 0 position earlier Pleasant smooth sauna bath temperature is about 70 C Rearr...

Page 4: ...SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED AT THE SAME ZONE 2 3 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the...

Page 5: ...to enhance ventilation between the stones Do not bend the heating elements together or against the frame Rearrange the stones regularly at least once a year and replace small and broken stones with n...

Page 6: ...desired time If the switch has not travelled back to 0 position after finishing bathing turn it to 0 manually 2 5 3 Thermostat The thermostat knob is next to the timer knob The further right clockwis...

Page 7: ...llation Check the following before installing the sauna heater 1 The ratio of the heater s input kW and the sauna room s volume m3 Volume input recommendations are presented in Table 1 on page 9 The m...

Page 8: ...pporting brackets so that the connection box and the knobs if there are any will be visible and easy to reach The highest part of the top should always be closest to the wall If this is not the case t...

Page 9: ...mm Stone kW Volume Height Side wall A mm In front of D mm To ceiling mm To the floor K mm B mm J mm min max Approx Approx kg kg min m max m min mm 4 5 3 6 1900 40 80 1100 120 135 245 20 28 6 0 5 9 190...

Page 10: ...e bleeder currents The moisture will be gone after a few heating sessions Do not connect the heater power supply through a ground fault interrupter However always adhere to the effective electrical sa...

Page 11: ...Signal lamp Kontrolleuchte lampe de signal l mpara de 55 S hk l mmityksen vuorottelu Alternering med elv rme Signal kontakt Steuerkontact f r Verrieglung anderer el Verbraucher Contact du signal Signa...

Page 12: ...OYKS 3 1 1 1 1 3 5401597 Thermostat OLHE 10 1 1 1 1 1 4 7712000 Cable clamp NKWA 1 1 1 1 1 5 7812550 Mains connector NLWD 1 1 1 1 1 1 6 7309523 Knob YWWA 13 1 2 2 2 2 7 5207680 Heating element SEPC 9...

Page 13: ...vironmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical a...