Helo FONDA DET Installation And User Manual Download Page 3

 

 

1.  Quick instructions for use of the sauna heater 

 

1.1  Check before taking a sauna bath 

 

1.  The sauna room is suitable for taking a sauna bath. 
2.  The door and the window are closed. 
3.  The sauna heater is topped with stones that comply with the manufacturer's recommendations,  
        the heating elements are covered with stones, and the stones are piled sparsely. 
 
NOTE! Ceramic rocks are not allowed. 
 
 

1.2  Operation of the sauna heater controls 

 

Refer to the specific control panel operating instructions. 
 
For additional information about enjoying a sauna bath, please visit our website a

www.tylohelo.com

 

 
 

2.  Information for users

 

 
Persons with reduced physical and mental capacity, sensory handicap, or little experience and knowledge 
about how the device is operated (e.g. children), should only operate the device while supervised or according 
to instructions given by the persons in charge of their safety. 
 
Make sure that children aren't playing with the sauna heater. 
 
 

2.1  Sauna room 

 
The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that store heat, such as 
tiled and plastered surfaces must be insulated. It is recommended to use wooden panel cladding inside the 
sauna room. If there are heat storage elements in the sauna room, such as decorative stone, glass etc., note 
that these elements may extend the pre-heating period even though the sauna room is otherwise well insulat-
ed (see page 6, section 3. Preparing for sauna heater installation). 
 
 
 
 

2.2  Heating the sauna 

 
Before turning the sauna heater on, make sure the sauna room is suitable for taking a sauna bath. When 
heated for the first time, the sauna heater may emit some odour. If you detect any odour while the sauna 
heater warms up, disconnect the sauna heater briefly, and air the room. Then you can turn the sauna heater 
on again.  

The sauna heater is turned on from the control panel that has controls for the heating temperature and 
time. 

The heating of a sauna should be started roughly an hour before you plan to take a sauna bath, so that the 
stones have time to heat up properly and the air warms up evenly in the sauna room. 

Do not put any objects on the sauna heater. Do not dry clothes on the sauna heater or anywhere in its 
vicinity.

 

 
 
 
 

Installation and User Manual  

FONDA DET

 

Summary of Contents for FONDA DET

Page 1: ...ELECTRIC SAUNA HEATER 1712 450 040518 1712 600 040518 1712 800 040518 CONTROL PANEL 1601 27 RA 27 T1 1601 34 RA 34 EC50 314 SKSM 208 2 A Installation and User Manual FONDA DET REWARD YOURSELF...

Page 2: ...stallation of control unit and sensor 8 3 4 Connection of the sauna heater to the mains 8 3 5 Location for the connection box 9 3 6 Principle image when T1 is used as control panel 10 3 7 Door switch...

Page 3: ...ll insulated All surfaces that store heat such as tiled and plastered surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storage elements...

Page 4: ...ilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 2 4...

Page 5: ...he heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 7 Any small stones in the package of stones must not b...

Page 6: ...olume Check page 8 Table 2 for a suitable fuse size A and the correct diameter of the power supply cable mm for the sauna heater in question Conform to the specified safe clearance around the sauna he...

Page 7: ...minimum mm Side wall A mm In front of D mm Ceiling F mm Floor K mm ca kg 4 5 6 0 8 0 4 6 5 9 8 12 1900 1900 1900 50 50 50 50 50 50 1150 1150 1150 100 100 100 20 20 20 Screws 6 x 40 2 pcs Screws 6 x 16...

Page 8: ...se H07RN F 60245 IEC 66 cables or a corresponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection...

Page 9: ...ded in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and heat resisting cables T 170 C The connection box must be clear of obstacles...

Page 10: ...Yellow Limiter Connector strip Heater Heater Sensor OLET 28 Control pannel T1 11 Valk Vit White Weiss 12 Musta Svart Black Schwarz 13 Vihre Gr n Green Gr n 14 Kelt Gul Yellow Gelb 15 Harm Gr Grey Gra...

Page 11: ...timer must have a door switch The control panel T1 and EC 50 can be fitted with either a Helo DSA 1601 35 RA 35 door switch adapter item number 001017 or a Helo door switch adapter item number 0043233...

Page 12: ...trique contact de signal Signal kontakt Signal contact Wisselschakelaar elektrische verwarming signaalcontact Signalkontakts Elektrik tte kontakt Sterowanie ogrzewaniem elektrycznym 3 Saunavalo Bastu...

Page 13: ...7812550 1 1 1 5 Relay Finder NRFA 3 2 5716203 2 2 2 6 Rocker switch OAAA 2 6101741 1 1 1 7 Rubber cover for rocker switch 7306008 1 1 1 8 Fuse holder NSPJ 2 7817536 2 2 2 9 Fuse F1 T1AH 7801711 2 2 2...

Page 14: ...ental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and ele...

Reviews: