Helo FONDA DET Installation And User Manual Download Page 10

 

 

 

3.6.   Principle image when T1 is used as control panel 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Image 5  Principle installation 
 

 

Installation and User Manual  

FONDA DET

 

10 

OLET 28 

1

   

 2

  3

   

4

11 12 13 14 15 16

11 12 13 14 15 16 17 18 19 20 21

4
3
2
1

4
3
2
1

1

   

2

   

3

   

4

OK

 

 

1 Blue 
2 White 
3 Red 
4 Yellow 

1 Blue 
2 White 
3 Red 
4 Yellow 

Limiter

 

Connector strip 

 

Heater

 

Heater

 

Sensor 
OLET 28 

Control pannel T1 

11    Valk      

Vit            White       Weiss 

12    Musta        Svart        Black       Schwarz 
13    Vihreä   

Grön        Green      Grün 

14    Kelt        

Gul          Yellow      Gelb 

15    Harm     

Grå          Grey        Grau 

16    Rosa          Ljusröd    Pink         Rose 
17    Sin             Blå           Blue         Blau 
18    Pun            Röd         Red          Rot 
 
 

Sensor  OLET 28 

Sauna heater 

Control panel 

T1 

LiYCY 10 x 0,25 

        Input 
   

 

   230V - 240V 1N~/ 2~ 
   230V 3~ 
   400V - 415V 3N~ 

NOTE!  See the sauna heater instruction  
for correct installation location 

 

Silicone 4 x 0,25 

Sensor cable 

Summary of Contents for FONDA DET

Page 1: ...ELECTRIC SAUNA HEATER 1712 450 040518 1712 600 040518 1712 800 040518 CONTROL PANEL 1601 27 RA 27 T1 1601 34 RA 34 EC50 314 SKSM 208 2 A Installation and User Manual FONDA DET REWARD YOURSELF...

Page 2: ...stallation of control unit and sensor 8 3 4 Connection of the sauna heater to the mains 8 3 5 Location for the connection box 9 3 6 Principle image when T1 is used as control panel 10 3 7 Door switch...

Page 3: ...ll insulated All surfaces that store heat such as tiled and plastered surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storage elements...

Page 4: ...ilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 2 4...

Page 5: ...he heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 7 Any small stones in the package of stones must not b...

Page 6: ...olume Check page 8 Table 2 for a suitable fuse size A and the correct diameter of the power supply cable mm for the sauna heater in question Conform to the specified safe clearance around the sauna he...

Page 7: ...minimum mm Side wall A mm In front of D mm Ceiling F mm Floor K mm ca kg 4 5 6 0 8 0 4 6 5 9 8 12 1900 1900 1900 50 50 50 50 50 50 1150 1150 1150 100 100 100 20 20 20 Screws 6 x 40 2 pcs Screws 6 x 16...

Page 8: ...se H07RN F 60245 IEC 66 cables or a corresponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection...

Page 9: ...ded in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and heat resisting cables T 170 C The connection box must be clear of obstacles...

Page 10: ...Yellow Limiter Connector strip Heater Heater Sensor OLET 28 Control pannel T1 11 Valk Vit White Weiss 12 Musta Svart Black Schwarz 13 Vihre Gr n Green Gr n 14 Kelt Gul Yellow Gelb 15 Harm Gr Grey Gra...

Page 11: ...timer must have a door switch The control panel T1 and EC 50 can be fitted with either a Helo DSA 1601 35 RA 35 door switch adapter item number 001017 or a Helo door switch adapter item number 0043233...

Page 12: ...trique contact de signal Signal kontakt Signal contact Wisselschakelaar elektrische verwarming signaalcontact Signalkontakts Elektrik tte kontakt Sterowanie ogrzewaniem elektrycznym 3 Saunavalo Bastu...

Page 13: ...7812550 1 1 1 5 Relay Finder NRFA 3 2 5716203 2 2 2 6 Rocker switch OAAA 2 6101741 1 1 1 7 Rubber cover for rocker switch 7306008 1 1 1 8 Fuse holder NSPJ 2 7817536 2 2 2 9 Fuse F1 T1AH 7801711 2 2 2...

Page 14: ...ental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and ele...

Reviews: