3
Image 1
Image 2
Image 3
Image 4
Image 5
INSTALLATION OF HEATER STONES AND INSULATION RINGS
Before the installation of heater stones and insulation rings the
heater has to be installed into its location and its electrical
connections secured. Moving of the heater while it is full of
heater stones may damage the heater / floor.
-
Remove the insulation rings before the loading of the heater stones.
-
Lift the top insulation ring directly upwards.
-
Loosen the allen screws (2 pcs, see arrows in figure 3) on the
inside circumference of the rotating ring so that the rotating ring
can be lifted away. NOTE! Don't loosen the screws entirely as
they may fall inside the heater.
-
Next lift the lower insulation ring from its location.
-
Load the heater stones meant to be inside the heater as shown in
the figure. The stones must cover the resistors (see figure 1).
-
First install the lower insulation ring in its place (see figure 2).
-
The insulation ring must be set in its location and it must not be
left to rest on the heater stones.
-
Next install the rotating ring with lids into its location (see figure 3).
-
Turn the lid to the desired position before tightening the locking
screws.
-
NOTE! The lid, however, must not direct steam / hot air directly
against the wall or some other obstacle. Note the protection
distances!
-
Tighten the screws so that the rotating ring is not able to move.
However, do not use excessive strength while tightening. This
may make the removal of the ring difficult, for example in
connection with maintenance.
-
Check finally that the rotating ring stays in its place also when
the lid is opened.
-
Next install the control pads of the top insulation ring
(3 pcs, see figure 4) in their place.
-
The control pads have to be placed evenly on the circumference
of the lower insulation stone.
-
Finally install the upper insulation ring in its place as shown in
the figure.
-
Check also that the insulation rings are undamaged and in
their place.
-
NOTE! If the insulation ring or rings are cracked or are otherwise
damaged, the heater must not be used until the damaged insulation
rings have been replaced!