General:
-
Read the User Manual carefully.
-
These instructions should be kept by the user of the heater.
-
Turn the heater so that the lid over the electricity points can be opened easily for connection and
maintenance.
-
The mains switch and the overheating limiter reset are located in the bottom part of the front lid.
-
Before use it must be checked that the insulation rings are located correctly and are undamaged.
The stones are placed in the manner instructed in the User Manual. Otherwise the use of the heater
is prohibited and the guarantee will not compensate for any damages caused.
-
Pre-heat the heater at full power for at least 2 hours. Storage grease is removed from the heater by
this heating. If further odour still occurs, heat the heater for as long as necessary. Ensure sufficient
ventilation during the heating times. A door or a window must not be left open during the heating.
-
NOTE! All the capacity measurements have been calculated for fully heat-insulated saunas.
All reserving heaters, such as Rondo, require a fully heat-insulated sauna. The insulation has a
critical effect on the functioning of the sauna and therefore it is recommended that the heat insulation
is undertaken carefully.
-
The control panel is intended to be installed next to the heater in the area outlined in the manual.
-
Maximum heating time for the use of the sauna using full power is 2 hours.
-
Adhere to the given installation measurements.
-
Only one heater may be installed into a sauna.
-
Wood panelling is recommended as material for the walls and ceiling of the sauna.
-
NOTE! Prior to switching the heater on, ensure that the sauna room is ready for heating.
-
If any problems occur, contact the nearest authorized service agreement centre. Information can be
found in a separate appendix or via the internet address:
www.helo.fi
Installation of the sauna heater:
-
The heater represents an upright model standing on the floor. The foundation has to be solid as the
weight of the heater is approximately 130kg stones included.
-
The heater is installed using the adjustable legs.
-
The heater is fixed using the adjustable legs with the supplied metal fastenings which prevent the
change of protection distances during use.
Connecting the heater to the mains:
-
Connection of the heater and the control centre to the mains can only be carried out by an
authorised person in accordance with the current electricity regulations.
-
The heater is semi-connected to the mains with H07RN-F (VSN) or A07BB-F(VSB) rubber cable.
-
The heater has a connector (55) for the control of the alternating of the electrical heating. Voltage
enters the connector at the same time as the full power for resistors is in use.
-
When using the lighting control of the heater controller the maximum permitted load is 100W.
-
When testing the heater functions the heater should not be heated without the stones.
Heater stones
-
It is recommended that the stones used in the heater are the ones supplied by the manufacturer.
-
Wash and load the stones.
-
The stones should be sufficiently large in order to provide an airy loading which is not too dense.
-
Heat resistors must not be wedged together nor against the heater frame.
-
The largest stones in the stone packages are loaded below the resistors so that the radiation heat of
the resistors will not heat the base of the stone space.
-
The stones should be reloaded sufficiently often. A good rule of thumb is that annually there should
be as many reloadings as the times the sauna is being used in a week.
-
In connection with the reloading small and crumbled heater stones should be removed as they
prevent the transfer of the heat away from the resistors and thus significantly shorten the life cycle of
the resistors.
-
The guarantee will not compensate for any damage caused by small, crumbled, poor-quality
or tightly loaded stones!
-
Use of ceramic stones is strictly forbidden! The guarantee will not compensate any damage
caused by them!