background image

 

 

2

General: 
 

-

 

Read the User Manual carefully. 

-

 

These instructions should be kept by the user of the heater. 

-

 

Turn the heater so that the lid over the electricity points can be opened easily for connection and 
maintenance. 

-

 

The mains switch and the overheating limiter reset are located in the bottom part of the front lid. 

-

 

Before use it must be checked that the insulation rings are located correctly and are undamaged. 
The stones are placed in the manner instructed in the User Manual. Otherwise the use of the heater 
is prohibited and the guarantee will not compensate for any damages caused. 

-

 

Pre-heat the heater at full power for at least 2 hours. Storage grease is removed from the heater by 
this heating. If further odour still occurs, heat the heater for as long as necessary. Ensure sufficient 
ventilation during the heating times. A door or a window must not be left open during the heating.  

-

 

NOTE! All the capacity measurements have been calculated for fully heat-insulated saunas. 

All reserving heaters, such as Rondo, require a fully heat-insulated sauna. The insulation has a 
critical effect on the functioning of the sauna and therefore it is recommended that the heat insulation 
is undertaken carefully. 

-

 

The control panel is intended to be installed next to the heater in the area outlined in the manual. 

-

 

Maximum heating time for the use of the sauna using full power is 2 hours. 

-

 

Adhere to the given installation measurements. 

-

 

Only one heater may be installed into a sauna. 

-

 

Wood panelling is recommended as material for the walls and ceiling of the sauna. 

-

 

NOTE! Prior to switching the heater on, ensure that the sauna room is ready for heating. 

-

 

If any problems occur, contact the nearest authorized service agreement centre. Information can be 
found in a separate appendix or via the internet address: 

www.helo.fi

 

 
Installation of the sauna heater: 

 

-

 

The heater represents an upright model standing on the floor. The foundation has to be solid as the 
weight of the heater is approximately 130kg stones included. 

-

 

The heater is installed using the adjustable legs. 

-

 

The heater is fixed using the adjustable legs with the supplied metal fastenings which prevent the 
change of protection distances during use. 

 

Connecting the heater to the mains: 

 

-

 

Connection of the heater and the control centre to the mains can only be carried out by an 
authorised person in accordance with the current electricity regulations. 

-

 

The heater is semi-connected to the mains with H07RN-F (VSN) or A07BB-F(VSB) rubber cable. 

-

 

The heater has a connector (55) for the control of the alternating of the electrical heating. Voltage 
enters the connector at the same time as the full power for resistors is in use. 

-

 

When using the lighting control of the heater controller the maximum permitted load is 100W.

 

-

 

When testing the heater functions the heater should not be heated without the stones.  

 

Heater stones 

 

-

 

It is recommended that the stones used in the heater are the ones supplied by the manufacturer. 

-

 

Wash and load the stones. 

-

 

The stones should be sufficiently large in order to provide an airy loading which is not too dense. 

-

 

Heat resistors must not be wedged together nor against the heater frame. 

-

 

The largest stones in the stone packages are loaded below the resistors so that the radiation heat of 
the resistors will not heat the base of the stone space. 

-

 

The stones should be reloaded sufficiently often. A good rule of thumb is that annually there should 
be as many reloadings as the times the sauna is being used in a week.  

-

 

In connection with the reloading small and crumbled heater stones should be removed as they 
prevent the transfer of the heat away from the resistors and thus significantly shorten the life cycle of 
the resistors. 

-

 

The guarantee will not compensate for any damage caused by small, crumbled, poor-quality 
or tightly loaded stones! 

-

 

Use of ceramic stones is strictly forbidden! The guarantee will not compensate any damage 
caused by them!

 

Summary of Contents for 1108-451-1705

Page 1: ...GENUINE SAUNA STEAM User Manual RONDO Type information Power 1108 961 1705 9 6kW 1108 651 1705 6 5kW 1108 451 1705 4 5kW Voltage 400 V 3N 7014056 314 SKLH 30 D...

Page 2: ...resents an upright model standing on the floor The foundation has to be solid as the weight of the heater is approximately 130kg stones included The heater is installed using the adjustable legs The h...

Page 3: ...set in its location and it must not be left to rest on the heater stones Next install the rotating ring with lids into its location see figure 3 Turn the lid to the desired position before tightening...

Page 4: ...pressed down Activates a relay on the circuit board The heater has its own connector for the lighting controller voltage 230 VAC and the maximum power 100W A led is activated next to the light button...

Page 5: ...Control panel error displays When certain error conditions appear the control panel is able to identify via its display what may cause the distortion When a distortion occurs the displays will show an...

Page 6: ...est set temperature will always be stored in the memory The temperature can be set with the and buttons once the upper display is flashing The setting range for the simmering mode is 150 250 C The cha...

Page 7: ...pressing again the OK button or alternatively by waiting for about 3 seconds and then the controller moves automatically to the next setting point Next the lower display shows the latest set sauna tim...

Page 8: ...a use time has expired it can be done by pressing the OK button and by pressing and holding the button down for about 3 seconds Then the heater is transferred back to the simmering mode and the stone...

Page 9: ...0 Adjustable leg Fixing iron Heater leg Floor fixing skrew The main switch and the overheating limiter reset Heater installation measurements NOTE All the measurements given are in millimetres All the...

Page 10: ...ONTROL THERMOSTAT IS LOCATED AT THE SAME ZONE 2 3 1 L L L 1 2 3 U V W 1 2 3 N L1 L2 L3 N N L 1 2 3 4 5 6 7 8 9 OLEA 71 1 2 3 P P P 9 8 7 3 6 2 5 1 4 K2 1 0 control T2 T1 K K Tx Rx A2 A1 light 55 Pu Ke...

Page 11: ...ight during the installation 2 Place the controller as accurately as possible on the wooden base and drill a 2 3mm hole through the upper plank to the wooden base The depth of the hole has no signific...

Page 12: ...n the recess meant for it 5 Locate the controller frame into its place The frame is located in its place by pressing with the hands Remove using for example a knife the pre worked plastic part reserve...

Page 13: ...ctions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of...