Helo 1107-60-040517 Installation And User Manual Download Page 5

 

 

 

 

2.2.  Various stages of the installation 

 
 

With the adjustment legs driven in, the mounting height of the  
sauna heater wall mount is 750mm from the floor. 
 
The adjustment legs can be adjusted 15mm in case the floor is  
inclined. After the mounting, check that both adjustment legs are  
evenly against the floor. 
 
The distance between the holes for the mount in the wall is 240mm. 
 
 
 
Parts for wall mounting: 
 
   - sauna heater locking wedges (A) 

2 pcs 

   - wall fastening (B) 

 

1 pc 

   - sheet metal screw 4.2 x 13mm 

2 pcs 

   - build screw 6 x 40mm      

2 pcs 

 
 
Pass the locking wedges (A) through the holes in the heater so 
that the ingoing part is turned upwards. 
 
The wall mount (B) is attached to the wall so that the holes where  
the locking wedges are secured to are upwards.  
 
The mount may also be attached directly to the sauna heater.  
Mark the locations of the screws on the wall and, if necessary,  
drill small holes and mount the sauna  
heater then to the wall with the screws provided. 
 
The picture shows how the wall mount should be attached  
to the sauna heater. The locking wedges are attached to  
the wall mount with the sheet metal screws. 
 

 

              Figure 1 Mounting the sauna heater to the wall 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and User Manual  

HELO Roxx Premium

 

A

B

Borr diam. o 3,5 mm

Mi

n

 7

5

0

 m

m

  

Ma

x

 7

6

5

 m

m

Min.
240 mm

240

2

4

0

 m

m

 

240mm 

Summary of Contents for 1107-60-040517

Page 1: ...A HEATER 1107 60 040517 1107 90 040517 230V 240V 1N 2 230V 3 400V 415V 3N CONTROL PANEL 1601 31 RA 31 Trend 1601 33 RA 33 Premium Wifi 314 SKLT 72 3 A Installation and User Manual HELO Roxx Premium RE...

Page 2: ...2 12 Heating the sauna 11 2 13 Sauna heater stones 12 2 14 If the sauna heater will not heat up 12 2 15 Door switch 13 2 16 Principle image when RA 33 Premium is used as control panel 14 2 17 BWT tech...

Page 3: ...these elements may extend the pre heating period even though the sauna room is otherwise well insulated see page 4 section 1 Preparing for sauna heater installation 1 3 Operation of the sauna heater...

Page 4: ...should be enough room around the sauna heater controls for maintenance purposes Also a doorway can be considered as a maintenance area Only a single sauna heater is allowed per sauna room 2 1 Installa...

Page 5: ...edges A through the holes in the heater so that the ingoing part is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are upwards The mo...

Page 6: ...nsor is installed on the sauna room wall no more than 500 mm from the ceiling Once the additional sensor has been connected to the circuit board it is automatically acti vated This means that the temp...

Page 7: ...bove the heater and in line with the centre line of the heater Do not install the sensor anywhere else 100 490 100 10 280 D 10 40 100 490 100 10 280 D 10 40 Sensor OLET 31 Sensor OLET 31 Sensor OLET 3...

Page 8: ...uses NOTE Controlling the lights in the sauna with the circuit board is only possible with resistive loads incandescent light bulbs The circuit board relay cannot withstand capacitive loads switched m...

Page 9: ...rs 3 and 4 of a RJ10 circuit board The recommended cable size is AWG 24 or 26 The maximum length of an AWG 24 cable is 200 m when using a Trend controller The maximum length of an AWG 26 cable is 130...

Page 10: ...k l mmityksen vuorottelu Alternering med elv rme Signal kontakt Signal contact Contac t du signal Signaalcontact Contacto se al 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light clairage du sau...

Page 11: ...THERMOSTAT IS LOCATED IN THE SAME ZONE 2 12 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna h...

Page 12: ...iled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 6 Any small stones in the pac...

Page 13: ...r edge of the door at least 300 mm from the inner corner The switch part is installed on the door frame and the magnet is installed on the door The distance between the switch and the magnet is 18 mm...

Page 14: ...cuit board OLEA 103 1 Blue 2 White 3 Red 4 Yellow End stop return acknowledgement Adapter circuit board OLEA 103 RJ10 intermedia cable Heater Control panel RA 33 Premium Control panel RA 33 Premium Se...

Page 15: ...emoved every so often The stones surrounding the tank must be removed during cleaning so that the tank can be lifted more easily When the water is boiling the moisture levels in the sauna remain high...