1.1  Check before taking a sauna bath 

 

1. The sauna room is suitable for taking a sauna bath. 
2. The door and the window are closed. 
3. The sauna heater is topped with stones that comply with the manufacturer's 
recommendations, the   heating elements are covered with stones, and the stones are 
piled sparsely. 

 
NOTE! Ceramic rocks are not allowed. 

The heater's main switch is located at the bottom of the heater, on the right side as seen 
from the front.  

The main switch is marked with a 0 

 1 sticker. 

 

1.2  Sauna room 

 

The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that 
store heat, such as tiled and plastered surfaces must be insulated. It is recommended to use 
wooden panel cladding inside the sauna room. If there are heat storage elements in the sau-
na room, such as decorative stone, glass etc., note that these elements may extend the pre-
heating period even though the sauna room is otherwise well insulated (see page 4, section 
1. Preparing for sauna heater installation). 
 
 

1.3  Operation of the sauna heater controls 

 

This appliance may not be used by children aged less than eight years, by persons with 
reduced physical, sensory or mental capabilities, or by persons lacking experience and 
knowledge regarding its operation only if such have been given instructions on the safe use 
of the device and the risks involved. Children must not be allowed to play with the appliance 
or to clean and service it without supervision. (7.12 EN 60335-1:2012) 

 
 

1.4  Operation of the sauna heater controls 

 

 

Refer to the specific control panel operating instructions. 

Pleasant, smooth sauna bath temperature is about 70 °C. 

If you encounter any problems, please contact the manufacturer's warranty service shop.  

For additional information about enjoying a sauna bath, please visit our website at  : 

www.tylohelo.com

 

 
 
 
 
 
 
 
 

Installation and User Manual  

HELO Roxx Premium

 

Summary of Contents for 1107-60-040517

Page 1: ...A HEATER 1107 60 040517 1107 90 040517 230V 240V 1N 2 230V 3 400V 415V 3N CONTROL PANEL 1601 31 RA 31 Trend 1601 33 RA 33 Premium Wifi 314 SKLT 72 3 A Installation and User Manual HELO Roxx Premium RE...

Page 2: ...2 12 Heating the sauna 11 2 13 Sauna heater stones 12 2 14 If the sauna heater will not heat up 12 2 15 Door switch 13 2 16 Principle image when RA 33 Premium is used as control panel 14 2 17 BWT tech...

Page 3: ...these elements may extend the pre heating period even though the sauna room is otherwise well insulated see page 4 section 1 Preparing for sauna heater installation 1 3 Operation of the sauna heater...

Page 4: ...should be enough room around the sauna heater controls for maintenance purposes Also a doorway can be considered as a maintenance area Only a single sauna heater is allowed per sauna room 2 1 Installa...

Page 5: ...edges A through the holes in the heater so that the ingoing part is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are upwards The mo...

Page 6: ...nsor is installed on the sauna room wall no more than 500 mm from the ceiling Once the additional sensor has been connected to the circuit board it is automatically acti vated This means that the temp...

Page 7: ...bove the heater and in line with the centre line of the heater Do not install the sensor anywhere else 100 490 100 10 280 D 10 40 100 490 100 10 280 D 10 40 Sensor OLET 31 Sensor OLET 31 Sensor OLET 3...

Page 8: ...uses NOTE Controlling the lights in the sauna with the circuit board is only possible with resistive loads incandescent light bulbs The circuit board relay cannot withstand capacitive loads switched m...

Page 9: ...rs 3 and 4 of a RJ10 circuit board The recommended cable size is AWG 24 or 26 The maximum length of an AWG 24 cable is 200 m when using a Trend controller The maximum length of an AWG 26 cable is 130...

Page 10: ...k l mmityksen vuorottelu Alternering med elv rme Signal kontakt Signal contact Contac t du signal Signaalcontact Contacto se al 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light clairage du sau...

Page 11: ...THERMOSTAT IS LOCATED IN THE SAME ZONE 2 12 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna h...

Page 12: ...iled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 6 Any small stones in the pac...

Page 13: ...r edge of the door at least 300 mm from the inner corner The switch part is installed on the door frame and the magnet is installed on the door The distance between the switch and the magnet is 18 mm...

Page 14: ...cuit board OLEA 103 1 Blue 2 White 3 Red 4 Yellow End stop return acknowledgement Adapter circuit board OLEA 103 RJ10 intermedia cable Heater Control panel RA 33 Premium Control panel RA 33 Premium Se...

Page 15: ...emoved every so often The stones surrounding the tank must be removed during cleaning so that the tank can be lifted more easily When the water is boiling the moisture levels in the sauna remain high...

Reviews: