STEP 1VH –
Press
and
simultaneously for three seconds, or until display changes and
release, then press
and
simultaneously and release. If screen in step 2VH does not appear
in 5 seconds the lock on the valve is activated.
STEP 2VH
–
Days, total since start-up:
This display shows the total days since startup. Press
the NEXT button to go to Step 3VH. Press REGEN to return to previous step.
STEP 3VH
–
Regenerations, total number since start-up:
This display shows the total number
of regenerations that have occurred since startup. Press the NEXT button to go to Step 4VH.
Press REGEN to return to previous step.
STEP 4VH
–
Volume, total used since start-up:
This display shows the total gallons treated
since startup. This display will equal zero if a water meter is not installed. Press NEXT button to
go to Step 5VH. Press REGEN to return to previous step.
STEP 5VH
–
Error Log history:
up to 10 errors. Press
and
buttons to view each recorded
error. If no errors have occurred " E 1 – –" is displayed. Press NEXT to exit valve history.
STEP 1VH
VALVE HISTORY
STEP 2VH
970
DAY
STEP 3VH
235
STEP 4VH
175
GAL
x1000
(Can not be reset)
REGEN
STEP 5VH
E1101
CYCLE SEQUENCE
Cycle Sequence instructions allows the operator to set the order of the
cycle. The Softener System Setup allows the operator to set how long the
cycles will last. The operator may choose up to 9 cycles in any order.
END must be used as the last cycle option. The SOFTENING cycle
should only be used in brine prefill applications to allow salt to dissolve.
The following is an example of how to set a valve so that when regenera
-
tion is initiated, BACKWASH occurs first, dn BRINE occurs second, RINSE occurs third, and FILL occurs fourth.
Cycle Options
BACKWASH
DN BRINE
FILL
RINSE
SOFTENING
END
STEP 1CS
STEP 2CS
1.0
SET
STEP 1 CS –
Press NEXT and
simultaneously until display changes, then release. Again
press NEXT and
simultaneously and release. If screen in step 2CS does not appear in 5 sec
-
onds the lock on the valve may be activated.
STEP 2 CS
–
Meter Size.
Use the
or
to select 1 for 1" ProMate-1.0 valve. Press NEXT to go
to Step 3CS. Press REGEN to exit cycle sequence.
➞
➞
➞
➞
➞
➞
➞