![Hellenbrand H-125 HE Series Owner'S Manual Download Page 35](http://html1.mh-extra.com/html/hellenbrand/h-125-he-series/h-125-he-series_owners-manual_2121515035.webp)
35
H125 SPECIFICATIONS
Model
H125-32-10
H125-48
H125-64
H125-96
H125-128
H125-160
H125-192
Factory Regeneration Settings
Cycle 1
Fill
Minutes
6.7
10
13.5
20
27
33.5
40
Gallons
3.35
5
6.75
10
13.5
16.75
20
Cycle 2
Softening
Minutes
120
120
120
120
120
120
120
Gallons
0
0
0
0
0
0
0
Cycle 3
Backwash Minutes
8
8
8
8
8
8
8
Gallons
17.6
17.6
33.6
33.6
42.4
60
60
Cycle 4
Brine DrDN Minutes
60
60
68
68
68
68
68
Gallons
19.2
22.2
43.52
48.28
74.8
95.2
122.4
Cycle 5
Rinse
Minutes
4
4
4
4
4
4
4
Gallons
8.8
8.8
16.8
16.8
21.2
30
30
Cycle 6
Optional
Total Regen Gallons
48.95
53.6
100.67
108.68
151.9
201.95
232.4
*Calculations are based on factory medium salt setting @ 50 psi
Lbs. Min.
5/3.4
7.5/5
10/6.7
15/10
20/13.5
25/17
30/20
6/4
9/6
12/8
18/12
24/16
30/20
36/24
10/6.7
15/10
20/13.5
30/20
40/27
50/33.5
60/40
15/10
22.5/15
30/20
45/30
60/40
75/50
90/60
20,000
30,000
40,000
60,000
80,000
100,000
120,000
22,926
34,389
45,852
68,778
91,704
114,630
137,556
28,000
42,000
56,000
84,000
112,000
140,000
168,000
31,995
47,992
63,990
95,985
127,980
159,975
191,970
22
19
25
24
25
27
26
31
28
34
34
34
37
34
14
14
30
35
40
60
60
1
1.5
2
3
4
5
6
10X44
10X54
13X54
14X65
16X65
18X65
18X65
Recommended Brine Tank Size
18X40
18X40
18X40
24X50
24X50
24X50
24X50
3/26
3/26
3/26
6/65
6/65
6/65
6/65
NO GRID
NO GRID
NO GRID
NO GRID
NO GRID
NO GRID
NO GRID
Salt Storage Capacity in LBS
412
412
412
916
916
916
916
BLFC on Valve
YES
YES
YES
YES
YES
YES
YES
Brine Valve
474
474
474
474
474
474
474
BLFC at Brine Tank
NO
NO
NO
NO
NO
NO
NO
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
2.2
2.2
4.2
4.2
5.3
7.5
7.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
D-RED
E-WHITE
G-YELLOW
H-GREEN
I-ORANGE
J-LT BLUE
K-LT GREEN
0.22
0.27
0.46
0.46
0.56
0.7
0.75
0.32
0.37
0.64
0.71
1.1
1.4
1.8
1,400
2,100
2,800
4,200
5,600
7,000
8,400
1.25"
1.25"
1.25"
1.25"
1.25"
1.25"
1.25"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
158
185
241
300
396
481
531
110280
110281
110282
110283
110284
110285
110286
** High Salting may require optional Grid or larger brine tank
Factory default setting are shown in bold
* Service Flows are with Hub and Lateral distributors and may be lower with a Stack distributor
Demand Recall set points are factory set at 85% of service Flow Rate
Factory meter GALLON setting is 2/3 of capacity divided by 20 g/g of hardness for single softeners
Recommended minimum pipes sizes are copper pipe equivalent, when using PEX increase one nominal size
800521 Rev G
*Shipping weights include skids
6/1/2018
H125 Specifications
Stock Code Number
Factory Meter Setting (for single unit)
Size of connections
Inlet / Outlet
Drain line
Brine Line Size
DLFC (gpm)
BLFC (gpm)
Injector Size
Injector Draw Rate @ 50 psi (gpm)
Injector Slow Rinse Rate @ 50 psi (gpm)
Resin Tank Size
Min/Max salt setting in Lbs
Shipping Weight
Drain Line
Brine Line
Brine Line
Recommended minimum pipe size
** Optional Grid Height
Continuous @ 15 psi loss
Service Flow Rates *
Peak @ 25 psi loss
Flint Underbed (Lbs)
High Capacity Resin (Cu. Ft.)
Capacity - Efficiency
Efficient - 4000 grains/lb
low Salt - 3821 grains/lb
Medium Salt - 2800 grains/lb
High Salt - 2133 grains/lb
Refill Lbs / Minutes
Efficient salt
Low Salt
Medium Salt
High salt