H125 SPECIFICATIONS

 

Model

H125-32-10

H125-48

H125-64

H125-96

H125-128

H125-160

H125-192

Factory Regeneration Settings
Cycle 1

Fill

Minutes

6.7

10

13.5

20

27

33.5

40

Gallons

3.35

5

6.75

10

13.5

16.75

20

Cycle 2

Softening

Minutes

120

120

120

120

120

120

120

Gallons

0

0

0

0

0

0

0

Cycle 3

Backwash Minutes

8

8

8

8

8

8

8

Gallons

17.6

17.6

33.6

33.6

42.4

60

60

Cycle 4

Brine DrDN Minutes

60

60

68

68

68

68

68

Gallons

19.2

22.2

43.52

48.28

74.8

95.2

122.4

Cycle 5

Rinse

Minutes

4

4

4

4

4

4

4

Gallons

8.8

8.8

16.8

16.8

21.2

30

30

Cycle 6

Optional

Total Regen Gallons

48.95

53.6

100.67

108.68

151.9

201.95

232.4

*Calculations are based on factory medium salt setting @ 50 psi

Lbs.    Min.

5/3.4

7.5/5

10/6.7

15/10

20/13.5

25/17

30/20

6/4

9/6

12/8

18/12

24/16

30/20

36/24

10/6.7

15/10

20/13.5

30/20

40/27

50/33.5

60/40

15/10

22.5/15

30/20

45/30

60/40

75/50

90/60

20,000

30,000

40,000

60,000

80,000

100,000

120,000

22,926

34,389

45,852

68,778

91,704

114,630

137,556

28,000

42,000

56,000

84,000

112,000

140,000

168,000

31,995

47,992

63,990

95,985

127,980

159,975

191,970

22

19

25

24

25

27

26

31

28

34

34

34

37

34

14

14

30

35

40

60

60

1

1.5

2

3

4

5

6

10X44

10X54

13X54

14X65

16X65

18X65

18X65

Recommended Brine Tank Size

18X40

18X40

18X40

24X50

24X50

24X50

24X50

3/26

3/26

3/26

6/65

6/65

6/65

6/65

NO GRID

NO GRID

NO GRID

NO GRID

NO GRID

NO GRID

NO GRID

Salt Storage Capacity in LBS

412

412

412

916

916

916

916

BLFC on Valve

YES

YES

YES

YES

YES

YES

YES

Brine Valve

474

474

474

474

474

474

474

BLFC at Brine Tank

NO

NO

NO

NO

NO

NO

NO

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

2.2

2.2

4.2

4.2

5.3

7.5

7.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

D-RED

E-WHITE

G-YELLOW

H-GREEN

I-ORANGE

J-LT BLUE

K-LT GREEN

0.22

0.27

0.46

0.46

0.56

0.7

0.75

0.32

0.37

0.64

0.71

1.1

1.4

1.8

1,400

2,100

2,800

4,200

5,600

7,000

8,400

1.25"

1.25"

1.25"

1.25"

1.25"

1.25"

1.25"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

158

185

241

300

396

481

531

110280

110281

110282

110283

110284

110285

110286

  ** High Salting may require optional Grid or larger brine tank
 

 Factory default setting are shown in bold

 * Service Flows are with Hub and Lateral distributors and may be lower with  a Stack distributor
Demand Recall set points are factory set at 85% of service Flow Rate
Factory meter GALLON setting is 2/3 of capacity divided by 20 g/g of hardness for single softeners
Recommended minimum pipes sizes are copper pipe equivalent, when using PEX increase one nominal size

800521 Rev G

*Shipping weights include skids

6/1/2018

H125 Specifications

Stock Code Number

Factory Meter Setting (for single unit)
Size of connections
  Inlet / Outlet
  Drain line

Brine Line Size
DLFC  (gpm)
BLFC  (gpm)
Injector Size
Injector Draw Rate @ 50 psi (gpm)
Injector Slow Rinse Rate @ 50 psi (gpm)

Resin Tank Size

  Min/Max salt setting in Lbs

Shipping Weight

  Drain Line
  Brine Line

  Brine Line
Recommended minimum pipe size

 ** Optional Grid Height

Continuous @ 15 psi loss

Service Flow Rates *

Peak @ 25 psi loss

Flint Underbed  (Lbs)
High Capacity Resin (Cu. Ft.)

Capacity - Efficiency
Efficient - 4000 grains/lb
low Salt - 3821 grains/lb

Medium Salt - 2800 grains/lb

High Salt - 2133 grains/lb

Refill Lbs / Minutes
Efficient salt
Low Salt

Medium Salt

High salt

Summary of Contents for H-125 HE Series

Page 1: ...vian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com p n 109122 Rev G Updated 8 30 18 2008 2018 System for Automatic Discharge Management U S Patent No 9 862 619 Method o...

Page 2: ...g Conditions 4 Pre Installation Check List 5 Bypass Valve Operation 5 Water Softener Disinfection 5 Installation Instructions 6 Programming 7 16 Set Time of Day Softener Setup Service Reminder Diagnos...

Page 3: ..._______________________________________________________ The average family uses 50 gallons per person daily for all water uses in the home about 30 gallons per person daily if soft water is not suppli...

Page 4: ...uple of weeks initially to determine how much salt you use this will depend on how much water you use As a rule of thumb with 20 gpg hard water about a 1 2 lb of salt per person per day is used In oth...

Page 5: ...a bypass valve Softening It is recommended that the conditioner be installed to soften both the hot and cold water supply A separate hard water faucet may be plumbed for drinking purposes if you desi...

Page 6: ...itting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Failure to do this could cause interior damag...

Page 7: ...ys BACKWASH Keep in backwash until water once again runs clear at the drain 10 Press REGEN button again until RINSE is displayed Allow rinse cycle to run its full course While the rinse cycle is finis...

Page 8: ...s sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a number allowable range from 1 to 28 a regeneration init...

Page 9: ...s of each cycle STEP 1S STEP 2S SOFTENING STEP 3S FILL 20 0 STEP 1S Press NEXT and simultaneously for 3 seconds If screen in Step 2S does not appear in 5 seconds the lock on the valve is activated STE...

Page 10: ...s capacity is affected by the fill time The grains capacity for the selected lbs salting should be confirmed by testing The capacity and hardness levels entered are used to automatically calculate res...

Page 11: ...ps registering flow which ever comes first Press NEXT to go to 19S for programming Service Alarm Relay activates on service alarm setting gallons time or both see step 21S Relay Triggered for Lockout...

Page 12: ...down arrows to select start time into regeneration to energize relay regeneration is defined by start of backwash or draw whatever comes first Range 20 500 minutes or select REGEN Select REGEN if rel...

Page 13: ...URN TO NORMAL MODE DIAGNOSTICS STEP 2D 2 DAYS SINCE REGEN STEP 3D 342 GAL STEP 1D DAY SINCE LAST REGEN STEP 1D Press or simultaneously for three seconds If screen in step 2D does not appear in 5 secon...

Page 14: ...on out is designated by sign Any time MAV is rebuilt or replaced reset diagnostics to reflect new drive characteristics STEP 6D 12 7 RETURN TO NORMAL MODE STEP 5D USAGE HISTORY DAY 108GAL GAL MAX FLOW...

Page 15: ...1 25 SET STEP 3CS OFF ALTERNATOR SYSTEM SET VALVE TYPE ALT A ALTERNATOR SYSTEM SET STEP 4CS STEP 5CS REFRESH RINSE SET TYPE MIN STEP 4CS Twin Alternating System Allows automatic alternation between t...

Page 16: ...ntrol Valve for Separate Source Operation Select Separate Source Enabled for control operation For separate source opera tion the three wire connector is not used Selection requires that a connection...

Page 17: ...fill flow control retainer assembly from the elbow Reinstall the elbow assembly and secure with the locking clip Disconnect the brine tube at the top of the salt keeper and force air into the brine tu...

Page 18: ...ans former if inadequate voltage 4 Low battery after power outage D1 If power outage occurred and battery on board has low voltage the microprocessor may not recover cleanly and display properly Disco...

Page 19: ...specification C Excessive water in brine tank C See problem 9 D Leaking faucets toilets etc D Repair or replace those items E Brine line flow control out of place E Replace Brine line flow control 7 L...

Page 20: ...eter D Unplug meter from PC board if LED display lights appropriately replace meter E Defective PC board E Replace PC board 15 Control does not display correct A Power outage 2 years A Reset time of d...

Page 21: ...SBV 8 Grid 1 104421 c 18X40 w 474 SBV 11 Grid 1 104423 d 24x50 w 474 SBV 6 Grid 1 104428 e 24x50 w 474 SBV 9 Grid 1 104423 f 18x40 w 474 SBV No Grid 1 104416 g 24x50 w 474 SBV No Grid 1 104426 h 30x50...

Page 22: ...H125 PC Board 1 5 101746 Drive Gear 12x36 3 6 101459 Drive Gear Cover 1 Not Shown 103723 Optional Relay Kit PCM 1 Not Shown 103729 Optional Relay Kit 120V Pigtail Not Shown 101880 Auxiliary Switch Ki...

Page 23: ...Plug 1 101825 Injector Assembly A Black 101826 Injector Assembly B Brown 101827 Injector Assembly C Violet 101828 Injector Assembly D Red 101829 Injector Assembly E White 5 101830 Injector Assembly F...

Page 24: ...ystems 1 102322 H125 H150 Refill Port Plug Assy 1 2 101154 H125 H150 BLFC Adapter 1 3 101414 Locking Clip 1 4 102417 H125 H150 Refill Retainer Assy 1 4 8 103590 1 2 Refill Elbow Assy 1 5 102153 O Ring...

Page 25: ...ine oils other hydrocarbon lubricants or spray silicone anywhere Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connec tion Teflon tape is not necess...

Page 26: ...ss Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 214 2 Bypass Valve Not Shown Bypass Vertical Adapter Assembly ORDER NO DESCRIPTION QTY 10...

Page 27: ...with a hammer Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connec...

Page 28: ...28 FLOW DIAGRAMS SERVICE AND BACKWASH FLOW DIAGRAMS RINSE AND FILL...

Page 29: ...or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Wrench part number is 102892 Loosens Drain Nut in Polytube Applications L...

Page 30: ...n gallons capacity reaches 0 Time of regeneration will not be allowed to be set because of regeneration will always occur when gallons capacity reaches 0 DELAY IMMEDIATE oFF Reserve capacity not autom...

Page 31: ...board The drive gear cover is held in place on the drive bracket by three clips The largest of the three clips is always orientated to the bottom of the drive bracket With the PC board facing up push...

Page 32: ...force the spacer stack assembly in The control valve body bore interior can be lubricated with silicone to allow for easy insertion of the entire stack Do not use silicone or any other type of lubric...

Page 33: ...urbine to remove it from the shaft Do not use a wire brush to clean the turbine Wipe with a clean cloth or chemically clean in dilute sodium bisulfite or vinegar The turbine can be immersed in the che...

Page 34: ...34 SERVICE RATES PRESSURE DROP CHARTS...

Page 35: ...e Tank NO NO NO NO NO NO NO 3 8 3 8 3 8 3 8 3 8 3 8 3 8 2 2 2 2 4 2 4 2 5 3 7 5 7 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 D RED E WHITE G YELLOW H GREEN I ORANGE J LT BLUE K LT GREEN 0 22 0 27 0 46 0 46 0 56 0...

Page 36: ...RANTY DOES NOT COVER defects caused by sand sediment or bacteria fouling accident fire flood Act of God misuse misap plication neglect alteration installation or operation contrary to Hellenbrand s pr...

Reviews: