FRONT COVER AND DRIVE ASSEMBLY

DRIVE CAP ASSEMBLY, DOWNFLOW PISTON, REGENERANT PISTON

AND SPACER STACK ASSEMBLY

1

15-V3005

Spacer Stack Assy

1

2

15-V3004

Drive Cap Assy.

1

3

15-V3135

O-Ring 228

1

4a

15-V3011*

Piston Downflow Assy.

1**

4b

15-V3011-01*

Piston Upflow Assy.

1

5

15-V3174

Regenerant Piston

1

6

15-V3180

O-ring 337-tank

1

7

15-V3105

O-ring distributor tube

1

Not Shown

15-V3193

Service Wrench

1

QTY.

ITEM NO.

ORDER NO.

DESCRIPTION

*15-V3011 is labeled with DN and 15-V3011-01 is labeled with UP.
Note: The regenerant piston is not used in backwash only applications.
**Standard Option.

After completing any valve maintenance involving the drive assemlby or the

drive cap assembly and pistons, press and hold NEXT and REGEN buttons for

3 seconds or unplug power source jack from the printed circuit board (black

wire) and plug back in.  This resets the electronics and establishes the service

piston position.  The display should flash all wording, then flash the software

version (ex: 154) and then reset the valve to the service position.

Do not use vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.  A silicon lubricant may be used on black o-rings but is not necessary.  

Avoid any

type of lubricants, including silicone, on red or clear lip seals.

After completing any valve maintenance involving the drive assemlby or the drive cap assembly and pistons, press and hold NEXT and REGEN buttons for 3 seconds

or unplug power source jack from the printed circuit board (black wire) and plug back in.  This resets the electronics and establishes the service piston position.  The

display should flash all wording, then flash the software version (ex: 154) and then reset the valve to the service position.

Figure 13

Figure 14

1

15-V3175-03-L

Blue Cover Assy w/H100 Label

1

2-6

15-V3002

Drive Assy.

*

2

15-V3107-01

Motor

1

3

15-V3106-01

Drive Bracket & Spring Clip

1

4

15-V3108

PC Board

1

5

15-V3110

Drive Gear 12x36

3

6

15-V3109

Drive Gear Cover

1

  Not Shown

15-V3186

Transformer 110V-12V

1

 Not Shown

15-V3115-01

Quick Reference Guide

1

QTY.

ITEM NO.

ORDER NO.

DESCRIPTION

7

All manuals and user guides at all-guides.com

Summary of Contents for Economical Water Conditioning System Series H-100

Page 1: ...05 Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 Phone 608 849 3050 Fax 608 849 7398 Web www hellenbrand com Email info hellenbrand com All manuals and user guides...

Page 2: ...g your water softener please contact the dealer who installed this system TABLE OF CONTENTS Job Specification Sheet Page 2 Operating Conditions 2 Soft Water Basics 3 Frequenty Asked Questions 3 Pre In...

Page 3: ...for buildup of insoluble materials It is recommended to periodically clean the salt keeper no matter what kind of salt you are using See page 9 miscellaneous 2 for details on cleaning REMEMBER Salt is...

Page 4: ...s built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment must be installed ahead of the water conditioner to correct the problem Drain Line The con...

Page 5: ...o connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Fai...

Page 6: ...starts coming out of the drain line open the by pass inlet valve all the way and allow to run out the drain until water clears Then slowly place the by pass into the normal operation mode by opening t...

Page 7: ...it Installer Displays Settings Step 3 Day Override This sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a n...

Page 8: ...TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the r...

Page 9: ...uns downward and is unobstructed When brine water quits running at the drain be sure to leave the drain valve open until you start the system up again 5 At this time the salt keeper has very little wa...

Page 10: ...en main or regenerant piston G Replace main or regenerant piston 3 Control valve does not regenerate A Transformer unplugged A Connect transformer automaticallly when REGEN button B No electric power...

Page 11: ...er ahead of softener C Resin bed mushing due to high amount C Rebed softener Install dechlorinaton system of oxidizers in water supply chlorine 14 Iron in softened water A Iron has fouled resin bed A...

Page 12: ...y 18x40 Blue 1 3 S75 1 c Brine Tank Assy 24x41 Black 1 3 531100302221 3 d Brine Tank Assy 24x50 Black 1 3 551100302221 3 7 3 8 x 6 Brine Line 1 2 H1023 06 8a 18x33 Brine Tank Tank Blue 1 2 1833BL b 18...

Page 13: ...the software version ex 154 and then reset the valve to the service position Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicon lubricant may be used on black o...

Page 14: ...washes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the...

Page 15: ...pe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of...

Page 16: ...ts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loos...

Page 17: ...1 15 V3151 Nut 1 Quick Connect 2 2 15 V3150 Split Ring 2 3 15 V3105 O Ring 215 2 4 15 V3188 01 Fitting 3 4 Brass Sweat 2 1 4 15 V3007 03 Fitting 3 4 Brass Sweat Asy 1 QTY ITEM NO ORDER NO DESCRIPTION...

Page 18: ...060 28 060 42 090 56 120 84 180 112 240 140 300 168 360 High Salting 24 230 32 310 32 310 48 460 64 620 96 930 129 240 161 550 193 860 Water Usage U S Gallons Normal Backwash Longer Backwash High Max...

Page 19: ...timated Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached AUTO On 0 oFF Reserve capacity not automatically...

Page 20: ...E ARE EXPRESSLY LIMITED TO A TERM OF TWO 2 YEARS SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU As a manufacturer we do not kno...

Reviews: