Installation and Operating Instructions
8
Fig .7
Cable runs under the casing . Cable
length from the wall at least 180 mm .
Fig .6
Ø 100 mm
Ø 120 mm*
r=58 mm
r=68 mm*
min . 90 mm
min
. 90 mm
Cable exit in
the dark
section
user-de-
fined .
Drill holes
Recommen-
ded
cable
exit optional
0 . . .-360 °,
ideally
in each
case 45 °
*
Type M1/120..
Fig .8
When installing the unit, the
guide vane
ö
must be moun-
ted vertically (as shown). Snaps
into place every 90° rotation.
Guide vane
ö
removable
Back
draught
shutter
ü
removable
ö
Apply
foam
strips
vertical for wall installation
top
bottom
Fig .9
ù
Condensate drain holes for
ceiling installation.
ò
Break out entry
knockout for cable for
surface mounting
ù
ä
ù
EN
– Duct inside diameter
M1
/100
F
= 100 mm or
M1
/120
F
= 120 mm
and distance to room corners: at least 90 mm.
– For surface installation, the casing is provided with a side entry knockout (Fig.9, Pos
ò
) for the cable!
– The mains supply cable is to be kept in such a way that no ingress of moisture is made possible along the
cable. The cable must not run over sharp edges!
2 . Drill holes:
Set casing against the wall, mark the holes and drill. Fasten with at least 2 screws and plugs.
3 . Back draught shutter and guide vane
– Guide vane must be mounted vertically (Fig.8).
Snaps into place every 90° rotation.
– Apply foam strips (Scope of delivery) prior to final installation (Fig.8)
ò