MiniVent M1/
100/120
F
Installation and Operating Instructions
3
EN
CHAPTER 2
GENERAL
OPERATING
INSTRUCTIONS
1 .9 Performance data
The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the local
supply network. The fan performances were established on a test stand according to DIN EN ISO 5801.
1 .10 Noise data
Noise data that refers to certain distances apply to free field conditions. With regard to installation, the sound pressure
level can differ significantly from the catalogue data, as it is highly dependent on the installation conditions, i.e. on the
absorption capability of the room and the room size among other factors.
2 .0 Personnel qualification
m
The electrical connection and commissioning as well as the installation, servicing and maintenance of the
fan must only be carried out by qualified electricians .
MiniVent
M1
/100/120
F
mini fans can be used by children over the age of 8 as well as persons with physical, sensory,
or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with regard to the safe
use of the unit and they understand the resulting risks. Children must not play with the unit. Cleaning or user main-
tenance must not be carried out by unsupervised children.
2 .1 Protection against contact
MiniVent
M1
/100/120
F
mini fans do not require protection guards, since they meet the requirements from DIN EN
60335-2-80 section 20.101.
2 .2 Motor protection
The motors of the MiniVent
M1
/100/120
F
have thermal contacts, which are wired in series with the coil and switch
off automatically and restart after cooling.
3 .0 Type overview MiniVent M1/1 . . F
M1
/100
F
with automatic humidity control
Ref no . 6175
M1
/120
F
with automatic humidity control
Ref no . 6364
3 .1 Technical data
M1/100 F
Impeller [mm]
Ø 92
Electrical supply line
NYM-O 3 x 1.5 mm²
Alternating current
1~
Protection category
IP45 (water jet protection)
Voltage/frequency
230 V, 50 Hz
Protection class
II
Power consumption [W] 9/5
Weight approx. [kg]
0.8
Rated current [mA]
0.06/0.04
Speed [1/min]
2650/2250
Flow volumes [m
3
/h] 90/75
M1/120 F
Impeller [mm]
Ø 111
Electrical supply line
NYM-O 3 x 1.5 mm²
Alternating current
1~
Protection category
IP45 (water jet protection)
Voltage/frequency
230 V, 50 Hz
Protection class
II
Power consumption [W]
13/10
Weight approx. [kg]
1.05
Rated current [mA]
0.09/0.08
Speed [1/min]
2350/2050
Flow volumes [m
3
/h] 170/150
CHAPTER 3
TECHNCAL DATA /
DIMENSIONS