background image

Bohrlöcher Ø 5 mm (Dübel) für Befestigungen
Fixation holes Ø 5 mm (plugs)
Trou de fixation Ø 5 mm (cheville)

Service und Information
D

HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen

F

HELIOS Ventilateurs · 157 avenue Charles Floquet · 93150 Le Blanc Mesnil

CH

HELIOS Ventilatoren AG · Steinackerstraße 36 · 8902 Urdorf / Zürich

GB

HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park · 

A

HELIOS Ventilatoren GmbH · Postfach 854 · Siemensstraße 15 · 6023 Innsbruck

Colchester · Essex · CO4 9HZ

Druckschrift-Nr

. 90

956

/

06.08

HelioVent

®

HVR 150

MONTAGESCHABLONE

Zu HVR-150-Typen (für Einbau in Glasscheiben
siehe Anleitung „Zubehör FES 150“

INSTALLATION PATTERN

for HVR 150 models (for window mounting see
instruction accessory “FES 150“

GABARIT D’ASSEMBLAGE

pour les modéles HVR 150 (pour montage sur vitre,
voir instruction “accessoire FES 150”

Summary of Contents for HelioVent HVR 150 Series

Page 1: ...ansportation storage or putting into operation are not liable for warranty OPERATION USE The fans are suitable for moving normal or slightly dusty almost non agressive and slightly humid air at temperatures of 20 C to 40 C and in the range of their performance characteristic curve For operation under difficult conditions i e high humidity longer period of standstill high pollution excessive workin...

Page 2: ...irection is suction across the motor For type HRV 150 2 RE it can be changed by changing the direction of rotation see wiring diagram In this case the performance of the fan is reduced by appro ximately 1 3 The sound data increases considerably at anomalous direction of rotation SPEED CONTOL The fans are speed controllable by voltage reduction In order to ensure sufficient cooling of the motor and...

Page 3: ...ion Extreme performance reduction can occur if the fan operating range is higher than the final point of operation causing also higher sound level Reasons for this can be the lack of sufficient streaming in of air or too high resistance of the ventilation system PUTTING INTO OPERATION The following checks are to be carried out check for operation according to the intended purpose of the fan compar...

Page 4: ...ning of 3 mm Power supply voltage and frequency must corre spond to the data on the motor rating plate The instroduction of the power cable must be done such that in case of water an entry along the power supply cable is impossible The connecting cable may not touch sharp objects For further working processes see Putting into operation MONTAGE Enlever la face C en utilisant une pièce de monnaie ou...

Page 5: ... grille Control by means of a cordswitch supplied or through the light switch as required Speed controller Reversing switch ESA 1 Order AA 0238 ESU 1 Order AA 0236 Electronic speed controller for infinitely variable speed control On off position BSX Order AA 0240 Same funktion as ESA 1 but additionally with reversing switch for extract and air supply For HVR 150 2 RE only DSEL 2 Order AA 1306 CERT...

Page 6: ...rich GB HELIOS Ventilation Systems Ltd 5 Crown Gate Wyncolls Road Severalls Industrial Park A HELIOS Ventilatoren GmbH Postfach 854 Siemensstraße 15 6023 Innsbruck Colchester Essex CO4 9HZ Druckschrift Nr 90 956 06 08 HelioVent HVR 150 MONTAGESCHABLONE Zu HVR 150 Typen für Einbau in Glasscheiben siehe Anleitung Zubehör FES 150 INSTALLATION PATTERN for HVR 150 models for window mounting see instruc...