Fenstereinbausatz FES 90

Window kit FES 90

Kit de montage sur vitre FES 90

Glasscheibe (Ein-

fach- oder Doppelglas)

a)

Zugentlastung

b)

2 x

Ventilator-Gehäuse

c)

Fassade

d)

3 x

Zugschalter

(entfällt bei externem

Betriebsschalter)

e)

max. 40

2 (3 x) 1

3

3

4

Zuleitung 2 x 1,5 mm

f)

2

N ca. 70 mm lang

g)

Litze

i)

Zugschalter

j)

Phase ca.

120 mm lang

h)

Zugentlastung

b)

L

1
2

N

L

N

Abb. 1/Fig. 1

Abb. 2/Fig. 2

Anschluß gemäß Schaltschema
Wiring diagram
Raccordement selon plan de branche ment

a)   Glass  pane   

(single or double glazing)

b) Cable clamp
c)  Fan casing 
d) Front grille

e)   Pull cord (not required for 

timer models or if switched 
via external switch.)

f) Supply 
g) N ca. 70 mm long
h)  Life ca. 120 mm long
i) Cable 
j)  Pull cord

Vitre 
(simple ou bouble vitrage)
Collier de blocage
Boîtier ventilateur
Façade

Interrupteur à tirette
(supprimé en cas de  
commande extérieure)
Alimentation
Neutre env. 70 mm long
Phase env. 120 mm long
Toron
Interrupteur à tirette

D  HELIOS Ventilatoren · Lupfenstraße 8 · 78056 VS­Schwenningen

CH HELIOS Ventilatoren AG · Tannstraße 4 · 8112 Otelfingen

A  HELIOS Ventilatoren GmbH · Siemensstraße 15 · 6023 Innsbruck

F  HELIOS Ventilateurs S.a.r.l. · Rue Louis Saillant ·  93605 Aulnay­sous­Bois

GB  HELIOS Ventilation Systems Ltd. · Felbridge Centre · Unit 1 

East Grinstead · West Sussex RH 19 1 XP

Druckschrift

­Nr. 97

015

­001/0218

Summary of Contents for FES 90

Page 1: ...rille 3 spacers threaded sleeve 2 foam gaskets pull cord cable clamp connection wire and 3 screws APPLICATION For use as a window kit in combination with the Helios R 90 and HR 90 K fan range Suitable for single secondary and double glazed windows Protection class IP20 PREPARATIONS Cut a hole of ø 103 2 mm in window pane The centre of the hole should be at least 120 mm away from the edge of the pa...

Page 2: ... distance between and or thickness of the panes 1 3 spacers 2 may have to be slid over the threaded sleeve with the open side towards the fan Insert one of the foam gaskets 3 between the pane and the nearest spacer The second gasket must be inserted between outer grille 4 and glass pane Ensure that the cutouts of the gaskets agree with those on the outer rille They must face dow nwards when mounti...

Page 3: ...diagram Replace front grille The front grille must only be remo ved when the unit is fully isolated from the supply ACCESSORIES OTHER CONTROLS The use of accessories not offered or recommended by Helios is not per mitted Any potential damage claims are void WARRANTY EXCLUSION OF LIABILITY If the preceding instructions are not observed all warranty claims are void The Helios warranty is limited to ...

Page 4: ...e e Pull cord not required for timer models or if switched via external switch f Supply g N ca 70 mm long h Life ca 120 mm long i Cable j Pull cord Vitre simple ou bouble vitrage Collier de blocage Boîtier ventilateur Façade Interrupteur à tirette supprimé en cas de commande extérieure Alimentation Neutre env 70 mm long Phase env 120 mm long Toron Interrupteur à tirette D HELIOS Ventilatoren Lupfe...

Reviews: