Druckschrift-Nr

. 91

560

/

09.07

Elektro-Heizregister EHR-R...
Electrical heating unit EHR-R...

Batterie de chauffe electrique pour gaines rondes 

EHR-R...

Type

Best.Nr.

Leistung

Schaltgruppen-

Strom-

Mindest-

passend zu

Anschluss

Abmessungen

Gewicht

Anz.

Aufnahme volumenstrom

Ventilator

Schaltplan

ca.

Type

Order No.

Output

Switchable Elements Amperage

Min Airflow

Suit Fan Ventilator

Connect. Diag No

Dimensions

Weight

Type

N° Réf.

Puissance

Nombre de groupes

Courant absorbé

Débit mini.

pour ventilateur de 

N° de branchement

Dimensions

Poids

Ø

en mm

Ø

H

L

kW

x kW

A

m

3

/h

NG mm

Nr.

mm

mm

mm

kg

Einphasen-Wechselstrom 1~, 230 V

/  1 Phase 230 V, 1ph  /  Monophasé 230 V

EHR-R 0,4/100

8708

0,4

1 x 0,4

1,7

45

100

813

100

185

325

2,0

EHR-R 0,8/125

8709

0,8

1 x 0,8

3,5

70

125

813

125

225

325

2,3

EHR-R 1,2/125

9433

1,2

1 x 1,2

5,2

70

125

813

125

225

325

2,4

EHR-R 1,2/160

9434

1,2

1 x 1,2

5,2

110

160

813

160

260

380

2,6

EHR-R 2,4/160

9435

2,4

1 x  2 x 1,2

10,4

110

160

814

160

260

380

3,0

EHR-R 1,2/200

9436

1,2

1 x 1,2

5,2

180 

200

813

200

300

380

2,8

EHR-R

2/200

9437

2,0

1 x 2,0

8,7

180 

200

813

200

300

380

3,2

Zweiphasen-Wechselstrom 2~, 400 V 

/  2 Phase 400 V, 2 ph  /  Biphasé  400 V

EHR-R 5/160

8710

5,0

1 x 2 x 2,5 parallel 12,5

110

160

815

160

260

380

4,0

EHR-R 5/200

8711

5,0

1 x 2 x 2,5 parallel 12,5

180

200

815

200

300

380

4,6

EHR-R 6/250

8712

6,0

1 x 2 x 3,0 parallel 15,0

270

250

815

250

350

380

7,3

EHR-R 6/315

8713

6,0

1 x 2 x 3,0 parallel 15,0

420

315

815

315

415

380

9,2

Drehstrom 3~, 400 V 

/  3 Phase 400 V, 3 ph  /  Triphasé 3~, 400 V

EHR-R 9/355

8656

9,0

1 x 3 x 3,0 im 

13,0

550

355

816

355

455

380

12,5

EHR-R 9/400

8657

9,0

1 x 3 x 3,0 im 

13,0

680

400

816

400

500

380

13,1

Maße in mm siehe Tabelle

Dimensions in mm, see table
Dimensions en mm, voir tableau

L

Service und Information
D

HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen

F

HELIOS Ventilateurs · Z.I. La Fosse à la Barbière · 2, rue Louis Saillant · 93605 Aulnay sous Bois Cedex

CH

HELIOS Ventilatoren AG · Steinackerstraße 36 · 8902 Urdorf / Zürich

GB

HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park · 

A

HELIOS Ventilatoren · Postfach 854 · Siemensstraße 15 · 6023 Innsbruck

Colchester · Essex · CO4 9HZ

5 6

4

2

1

Druckverlust EHR-R../100 –../200

p

Pa

7

V

.

m

3

/h

1 EHR-R 0,4/100
2 EHR-R 0,8/125

EHR-R 1,2/125

3 EHR-R

5/160

3

4 EHR-R 2,4/160
5 EHR-R

5/200

6 EHR-R 1,2/160

EHR-R

2/200  

7 EHR-R 1,2/200

ρ

= 1,20 kg/m

3

Druckverlust EHR-R../250 –../400

V

.

m

3

/h

1 EHR-R

6/250

2 EHR-R

6/315

3 EHR-R

9/355

4 EHR-R

9/400

1

2

3

4

ρ

= 1,20 kg/m

3

p

Pa

Temperatur-Erhöhung K

ρ

= 1,20 kg/m

3

9 kW

5

0,4

T

K

0,8

6

V

.

m

3

/h

1,2

2

2,4

Summary of Contents for EHR-R Series

Page 1: ...een the fan and the heater unit Always ensure measures are to be taken so that it is not possible to touch the heating elements The heater must be securely fixed in position For sa fety no inflammable materials must come into contact with the heater unit There must be kept at a minimum clearance distance of 150mm between the heater unit and any inflammable material The duc ting immediately upstrea...

Page 2: ...ith a heating element remains unused over a long period or has been stored in a damp environment it may be penetrated by damp This is not to be regar ded as a fault However a qualified electrician should carry out an inspection in order to ensure that no other fault is present If no additional fault is present the simplest solution is to connect the unit to without an earth leakage circuit breaker...

Page 3: ... Temperaturbegrenzer Thermal cutout Limiteur de température 50 C 120 C L1 N PE 1 230V EHR R 2 4 160 2 x 1 2 kW 92918 001 SS 813 28 07 04 5 6 PE 1 2 3 4 Heizstab Heating coil Spirale du filament EHR R 1 230V Heizregister Electric heater battery Batterie de chauffe électr Temperaturbegrenzer Thermal cutout Limiteur de température 50 C 120 C L1 N PE 1 230V EHR R 0 4 100 1 x 0 4 kW 0 8 125 1 x 0 8 kW ...

Page 4: ...auffe électr Temperaturbegrenzer Thermal cutout Limiteur de température 50 C 120 C L1 L2 PE 2 400V EHR R 5 160 2 x 2 5 kW 5 200 2 x 2 5 kW 6 250 2 x 3 0 kW 6 315 2 x 3 0 kW 92921 001 SS 816 04 07 03 5 6 PE 1 2 3 4 Heizstab Heating coil Spirale du filament EHR R 3 400V Heizregister Electric heater battery Batterie de chauffe électr Temperaturbegrenzer Thermal cutout Limiteur de température 50 C 120...

Page 5: ...ter thermal cutout has tripped Réarmement manuel aprés déclenchement limiteur de température TB 1 Ein Aus On Off Marche Arrêt Winter winter hiver Sommer summer été F3 Strömungswächter Air flow switch Contrôle de flux d air F1 Thermostat Temperature sensor Thermostat N1 Drehzahlsteuerung Speed control Régulateur de vitesse F2 Motorschutzschalter Motor protection Protection moteur S1 Heizstufenschal...

Page 6: ...2 5 parallel 12 5 110 160 815 160 260 380 4 0 EHR R 5 200 8711 5 0 1 x 2 x 2 5 parallel 12 5 180 200 815 200 300 380 4 6 EHR R 6 250 8712 6 0 1 x 2 x 3 0 parallel 15 0 270 250 815 250 350 380 7 3 EHR R 6 315 8713 6 0 1 x 2 x 3 0 parallel 15 0 420 315 815 315 415 380 9 2 Drehstrom 3 400 V 3 Phase 400 V 3 ph Triphasé 3 400 V EHR R 9 355 8656 9 0 1 x 3 x 3 0 im 13 0 550 355 816 355 455 380 12 5 EHR R...

Reviews: