
Air purifier AirPal Go 300/600 H
Installation and Operating Instructions
EN
EN
8
OFF.
- Date setting (HOrA): With MODE the data to be modified (day / time) is selected and with UP and DOWN the value is
modified. ON / OFF exits the date setting and returns to normal operating mode.
- Time programming (PrOG): With MODE the data to be modified (day / period / setpoint) is selected, and with UP and
DOWN the corresponding value is modified (time / setpoint). To deactivate the period, set the time to value: -. ON /
OFF exits the time schedule configuration, returning to normal operating mode. For more informations see „6.3 Para-
meter mode configuration“.
- Identifier display (ıd): The identifier configured in the regulator is displayed through serial communication.
The display is made by 5 digits of 7 segments
- Parameter mode (PAr) configuration menu: With MODE the parameter to be displayed is selected, and with UP and
DOWN its value is modified. With ON / OFF the parameter mode is exited, returning to the normal operating mode.
- Reset of filter G4 operating time (r g4): When entering this mode, the current operating hours of the G4 filter are
displayed. To reset the operating time (for example, resetting the hours by changing the filter), press ON / OFF. As
confirmation of the reset of the operating time, the display shows “HG OOOOO“, returning to the normal operating
mode. If ON / OFF is not pressed, after a few seconds the regulator returns to normal operating mode without having
reset the operating time.
- Reset the filter operating time H14 (r H 14): Upon entering this mode, the current operating hours of the H14 filter are
displayed. To reset the operating time (for example, resetting the hours by changing the filter), press ON / OFF. As
confirmation of the reset of the operating time, the display shows “HH OOOOO“, returning to the normal operating
mode. If ON / OFF is not pressed, after a few seconds the regulator returns to normal operating mode without having
reset the operating time.
- Controller reset (rESET): When the regulator is reset, the display shows “-----“, starting operation again after a few
seconds.
6�2 Display LCD
m
When powering the control panel, or after resetting it, it displays the following on the display:
• rP143 + : Display of the control panel
• v X.X: Indication of the control panel firmware version.
• wAit: Indication that the control panel is in the initialization process.
Icon
Indication
Fan status:
- Fan off: Icon off.
- Fan on: Icon on.
G4 filter status (1): + 1
- Clean filter: Icon off.
- Dirty filter: Icon on.
H14 filter status (2): + 2
- Clean filter: Icon off.
- Dirty filter: Icon on.
Fig�6
ATTENTION
Summary of Contents for AirPal Go 300 H
Page 2: ...DEUTSCH ...
Page 17: ...ENGLISH ...
Page 32: ...FRANÇAIS ...
Page 47: ...FR Purificateurs d air AirPal Go 300 600 H Notice de montage et d utilisation 15 ...