2
MiniVent M1
/100
F and M1
/120
F
Installation and Operation Instructions
1.8
General information
Intake air duct: Every room which must be ventilated must have an intake air opening (which cannot be closed) of
150 cm
2
free cross section.
1.9
Safety
- All servicing and installations may only be carried out by a certified electrician.
- The fans may be operated only with the rated voltage indicated on the type plate.
- Technical data on type plate are to be adhered to without fail.
- The degree of protection given on the type plate is only valid with designed installation in accordance
with these installation and operating instructions and with closed facia.
1.10
Electrical connection
All work must be carried out with the equipment fully isolated from the power supply. The electrical connec-
tion are to be carried out in accordance with the relevant wiring diagram and are only to be done by a certi-
fied electrician. The electrical connection must be fully isolated from the supply up to the final assembly!
All relevant safety regulation, national standards and norms are to be adhered to. An appliance is required for cut off
from the supply with a minimum of 3 mm contact opening of each pole.
The rated voltage and frequency must correspond with the data on the type plate. The insertion of mains supply cable
is carried out via a cable grommet which is included in the delivery. Never lead cable over sharp edges. The equip-
ment corresponds to protection IP 45 (jet water-protected).
In addition, they correspond to the safety class II.
1.11 Overview of types MiniVent M1/1.. F
M1
/100
F
with automatic humidity control
Ref:no. 6175
M1
/120
F
with automatic humidity control
Ref:no. 6364
1.12 Accessories
MF 100
Mounting flange
Ref:no. 6188
TWH 100
Telescopic wall sleeve
Ref:no. 6352
WES 100
Wall mounting kit
Ref:no. 0717
TWH 120
Telescopic wall sleeve
Ref:no. 6353
WES 120
Wall mounting kit
Ref:no. 0486
MBR
Mounting plate
Ref:no. 0281
WARNING
NOTE
☞
UK