Kleinlüfter - Mini fan - Mini ventilateur

Helios MiniVent

M1

/100

F

M1

/120

F

- mit Feuchteverlaufssteuerung und zwei Drehzahlstufen

- with automatic humidity control

- avec hygrostat électronique et deux vitesses

MONTAGE- UND BETRIEBSVORSCHRIFT

NR. 19053.003

INSTALLATION AND OPERATING INSTRUCTIONS

NO. 19053.003

NOTICE DE MONTAGE ET D’UTILISATION

19053.003

D

UK

F

IP 45

Helios Ventilatoren

Summary of Contents for 6175

Page 1: ...ufssteuerung und zwei Drehzahlstufen with automatic humidity control avec hygrostat électronique et deux vitesses MONTAGE UND BETRIEBSVORSCHRIFT NR 19053 003 INSTALLATION AND OPERATING INSTRUCTIONS NO 19053 003 NOTICE DE MONTAGE ET D UTILISATION N 19053 003 D UK F IP 45 Helios Ventilatoren ...

Page 2: ...e 2 KAPITEL 2 LIEFERUMFANG UND EINBAU Seite 3 2 0 Lieferumfang Verpackungseinheit Seite 3 KAPITEL 3 MONTAGE Seite 3 3 0 Vorbereitung zur Wand oder Deckenmontage Aufputz Seite 3 3 1 Kabelaustritt aus der Wand Seite 3 3 2 Bohrlöcher Seite 4 3 3 Wand oder Deckenmontage Seite 4 3 4 Installation der Abluftleitung Seite 4 3 5 Anschluss der Zuleitung Seite 5 3 6 Montageflansch MF 100 Zubehör Seite 6 KAPI...

Page 3: ... umge hend Schadensmeldung unter Hinzuziehung des Transportunternehmens veranlassen Bei nicht fristgerechter Reklamation gehen evtl Ansprüche verloren 1 5 Einlagerung Bei Einlagerung über einen längeren Zeitraum sind zur Verhinderung schädlicher Einwirkungen folgende Maßnahmen zu treffen Schutz des Motors durch trockene luft und staubdichte Verpackung Kunststoffbeutel mit Trockenmittel und Feuch t...

Page 4: ...sgemäßen Einbau gemäß dieser Montage und Betriebsvorschrift und bei geschlossener Fassade 1 10 Elektrischer Anschluss Vor allen Wartungs und Installationsarbeiten Jumper DIP Schalter Einstellungen oder vor Öffnen des An schlussraums ist das Gerät allpolig vom Netz zu trennen Der elektrische Anschluss darf nur von einer autori sierten Elektrofachkraft entsprechend den nachstehenden Anschlussplänen ...

Page 5: ...ür eine einfache Montage empfiehlt sich ein Austritt wie abgebildet Tüllenposition rechts oder links unten Die optimale Position liegt bei jeweils 45 wenn sich der Kabelaustritt direkt an der Position der Kabeltülle befindet Rohrinnendurchmesser M1 120 F 100 mm bzw M1 120 F 120 mm und Abstand zu Raum Ecken mindestens 90 mm MiniVent M1 1 F Abb 1 Fassade Anschlussraumabdeckung inkl 2x Befestigungssc...

Page 6: ...ckenmontage Bei der Deckenmontage muss besondere Sorgfalt geübt werden sonst erlischt die Gewährleistung 3 4 Installation der Abluftleitung Abluftleitungen die in kalten Zonen installiert werden müssen isoliert werden Bei stark auftretenden Kondensat muss in geeigneter Weise ein Wassersack im Rohrsystem mit integriert werden ACHTUNG Abb 5 Abb 4 Bei Einbau des Gerätes muss das Nachleitrad senkrecht...

Page 7: ...der IP Schutz 7 Drähte im Leitungskanal verlegen und laut Schaltplan Seite 9 anschließen MiniVent M1 100 F und M1 120 F Montage und Betriebsvorschrift 5 D Abb 6 Abb 7 1 Anschlussraumabdeckung in Nut einhängen auf Gehäuse drücken und Schrauben fest eindrehen 2 Fassade einschnappen Länge Einzeladern 100 mm Abisolierlänge 7 mm Mantelleitung bündig mit Kabelkanal abisolieren 100 mm 7 mm Abb 8 Nachleit...

Page 8: ...führt werden Die M1 100 F 120 F Kleinlüfter dürfen nicht mit Drehzahlstellern betrieben werden Die einschlägigen Normen Sicherheitsbestimmungen z B DIN VDE 0100 sowie die TAB der EVUs sind unbedingt zu beachten 4 1 Elektronische Steuerplatine M1 100 F serienmäßig mit Feuchteverlaufssteuerung und zwei Drehzahlstufen M1 120 F serienmäßig mit Feuchteverlaufssteuerung und zwei Drehzahlstufen EMV Vorsc...

Page 9: ...cklungstemperatur durch zu geringe Motorkühlung oder zu hohe Förder mitteltemperatur kann ebenfalls Ursache sein Anormale Geräusche können die Folge von ausgelaufenen Lagern sein Vibrationen und Schwingungen können ihre Ursache in einem unwuchtigen u U mit Schmutz beaufschlagten Laufrad oder in der Einbausituation haben Stark geminderte Leistung kann auftreten wenn der Ventilator gegen zu hohen An...

Page 10: ...r auf der Klemme 1 mit einem Taster eingeschaltet werden Tastimpuls mind 0 5 Sek Nachlauf 6 min 12 min 18 min 24 min DIP Schalter S1 2 3 siehe SS 941 WARNUNG Nach dem Abschalten der Klemme 1 läuft der Ventilator weiter und geht nach Ablauf der eingestellten Zeit automatisch aus Werkseinstellung ca 6 Minuten Der Betrieb mit Zeitfunktion ist der Feuchtesteuerung übergeordnet oder 3 Funktionsart Feuc...

Page 11: ...der Feuchtesteuerung deaktivieren rF rF SS 941 Einstellung der DIP Schalter M1 L N 1 2 Jumper 1 A B A B Manueller Eingang 1 2 L N Feuchte rF Funktions Eingang Kl 1 Kl 2 Kl 1 Kl 2 1 2 L N N L M1 F SS 948 2 r F 1 Anschluss Kunde Standard Entfeuchtungsbetrieb SCHALTPLAN ÜBERSICHT M1 100 F 120 F Rückspannung Raumbe leuchtung Glimmlampen Durch die Elektronik liegt an der Klemme 1 eine energieschwa che ...

Page 12: ...ge 3 CHAPTER 3 INSTALLATION Page 3 3 0 Preparation for wall or ceiling installation surface mounted Page 3 3 1 Cable exit from the wall Page 3 3 2 Drill holes Page 4 3 3 Wall or ceiling installation Page 4 3 4 Installation of extraction duct Page 4 3 5 Connection of the voltage supply Page 5 3 6 Mounting flange for MF 100 accessories Page 6 CHAPTER 4 ELECTRICAL CONNECTION Page 6 4 0 Electrical con...

Page 13: ...tion free and free of temperature variations When storing for several years or non rotation of motor an inspection of the bearings with possible relubrication and an electrical inspection to VDE 0701 and VDE 0530 are absolutely necessary before starting operation When trans hipping especially over longer distances check if the packing is adequate for method and manner of transportation Damages due...

Page 14: ...e only to be done by a certi fied electrician The electrical connection must be fully isolated from the supply up to the final assembly All relevant safety regulation national standards and norms are to be adhered to An appliance is required for cut off from the supply with a minimum of 3 mm contact opening of each pole The rated voltage and frequency must correspond with the data on the type plat...

Page 15: ... position is 45 each if the cable exit is directly at the position of the cable grommet Duct inside diameter M1 100 F 100 mm or rather M1 120 F 120 mm and distance to room corners at least 90 mm 3 MiniVent M1 100 F and M1 120 F Installation and Operation Instructions MiniVent M1 1 F fig 1 CHAPTER 2 SCOPE OF DELIVERY AND ASSEMBLY Facia Cover of control board including 2 x fastening screws Electroni...

Page 16: ...le 3 3 Wall or ceiling installation 3 4 Installation of extraction duct Extraction ducts which are installed in cold zones must be isolated With heavily occurring condensate a water pocket in the duct system must be integrated in an appropriate way fig 5 fig 4 With installation of the device the guide vane must be mounted vertically as shown Snaps into place every 90 rotation Ceiling suspension pr...

Page 17: ...licone Fig 6 Otherwise the IP protection expires 7 Run cable in conduit and connect according to wiring diagram page 9 5 MiniVent M1 100 F and M1 120 F Installation and Operation Instructions fig 6 fig 7 100 mm Snap in facia 7 mm 1 Press cover of control board on casing and fasten with screws 2 Snap in facia Length of single conductor 100 mm Length of stripped insulation 7 mm Strip plastic sheathe...

Page 18: ... regulation national standards and norms are to be adhered to 4 1 Electronic control board The electronic control board allows the operation with 2 speeds The control board is fitted into a splash proof casing M1 100 F with automatic humidity control M1 120 F with automatic humidity control EMV regulation norm Important indication for the electromagnetic compatibility Interference resistance accor...

Page 19: ...origins If the thermal protection trips this could be the result of dirt build up a hard running impeller and or bearings Too high winding temperature through insufficient motor cooling or too high air flow temperature could be the cause of disturbance Abnormal noises can mean worn out bearings Vibrations can originate from an unbalanced or dirty impeller or due to the installation Extreme perform...

Page 20: ... for the selected run on time using a short power on from a switch or a push button switch providing a short pulse of current minimum pulse 0 5 seconds The DIP switch setting SI 1 must be set to off and a cho sen run on time DIP switch setting SI 2 3 see wiring diagram SS 941 After switching off terminal 1 the fan keeps running and switches off after the run on time automatically Factory setting a...

Page 21: ...it oder Feuchtesteuerung deaktivieren rF rF SS 941 DIP switch adjustment M1 L N 1 2 Jumper 1 A B A B Manueller Eingang 1 2 L N Feuchte rF Funktions Eingang Kl 1 Kl 2 Kl 1 Kl 2 1 2 L N N L M1 F SS 948 2 r F 1 Connection client standard dehumidification operation WIRING DIAGRAMM OVERVIEW M1 100 F 120 F UK manual input input with two functions Inverse voltage room lighting glow lamp Due to electronic...

Page 22: ...2 0 Kit d installation Conditionnement Page 3 CHAPITRE 3 MONTAGE Page 3 3 0 Préparatifs en vue d un montage mural ou plafonnier apparent Page 3 3 1 Sortie murale du câble Page 3 3 2 Percements Page 4 3 3 Montage mural ou plafonnier Page 4 3 4 Installation du conduit d extraction Page 4 3 5 Raccordement électrique Page 5 3 6 Entretoise pour MF 100 accessoire Page 6 CHAPITRE 4 RACCORDEMENT ÉLECTRIQU...

Page 23: ...dure peut entraîner le rejet de la réclamation 1 5 Stockage Pour un stockage de plus longue durée se conformer aux instructions suivantes pour éviter toutes détériorations pré judiciables Protection du moteur grâce à un emballage sec étanche à l air et la poussière sac en matière synthétique contenant des sachets deshydrateurs et un indicateur d humidité Le matériel est à stocker dans un endroit a...

Page 24: ... d utilisation et avec la façade fermée 1 10 Raccordement électrique Mettre impérativement l appareil hors tension avant tous travaux d entretien de réglages de l interrupteur DIP ou l ouverture du boîtier de raccordement Le branchement électrique doit être réalisé conformément aux schémas de raccordement ci dessous uniquement par un électricien qualifié L alimentation électrique doit être mainten...

Page 25: ...ble se trouve directement à l endroit du guide Diamètre intérieur du conduit M1 100 F 100 mm ou bien M1 120 F 120 mm et distance jusqu aux coins de la pièce minimum 90 mm 3 F MiniVent M1 100 F et M1 120 F Notice de montage et d utilisation CHAPITRE 3 MONTAGE MiniVent M1 1 F Fig 1 CHAPITRE 2 KIT D INSTALLATION ET MONTAGE Façade Couvercle du bornier de raccordement avec 2 vis de fixation incluses Pl...

Page 26: ...age mural ou plafonnier En cas de montage plafonnier il faut être particulièrement méticuleux sous peine d annulation de garantie 3 4 Installation du conduit d extraction Isoler les conduits d extraction qui traversent les zones froides En cas de forte condensation dans le réseau prévoir un système de collecte et d évacuation de l eau Fig 5 Fig 4 Lors de la mise en place de l appareil le redresseu...

Page 27: ...ement prévu à cet effet et raccorder selon schéma page 9 5 F MiniVent M1 100 F et M1 120 F Notice de montage et d utilisation Fig 6 Fig 7 100 mm 7 mm Emboiter le couvercle de fermeture du bornier de raccordement 1 Emboiter le couvercle du bornier de raccorde ment dans la rainure appuyer sur le caisson et serrer fermement les vis 2 Clipper la façade Longueur de chaque fil 100 mm Dénuder le fil sur ...

Page 28: ...exemple DIN VDE 0100 ainsi que la norme C15 100 doivent impérative ment être respectées 4 1 Platine de commande électronique M1 100 F avec hygrostat électronique de série M1 120 F avec hygrostat électronique de série Prescription norme EMV Information importante au sujet des interférences électromagnétiques Résistance aux perturbations selon la norme DIN EN 55014 2 selon la forme de l impulsion et...

Page 29: ... des roulements Une température de bobinage trop élevée liée à un refroidissement moteur trop faible ou une température d air extrait trop importante peut également en être la cause Des roulements usés peuvent provoquer des bruits anormaux Les vibrations et les oscillations peuvent être le résultat d une turbine déséquilibrée le cas échéant recouverte de saleté ou d un défaut lié au montage Les pe...

Page 30: ...s de marche arrêt commun avec la lumière en employant ATTENTION un interrupteur bipolaire on peut pénétrer un court instant dans la pièce sans que le ventilateur se mette en route Réglage d usine environ 45 sec Inter rupteur DIP S1 1 SS 941 Nr 1 off fonction désactivée on 45 sec Mise en route par bouton poussoir Si le départ différé est désactivé le ventilateur peut être commandé par l in termédia...

Page 31: ... B Manueller Eingang 1 2 L N Feuchte rF Funktions Eingang Kl 1 Kl 2 Kl 1 Kl 2 Raccordement standard pour fonctionnement marche arrêt selon humidité ENSEMBLE DE SCHÉMAS ÉLECTRIQUES M1 100 F 120 F Marche forcée Commande voir notice Marche forcée Commande hygostat temporisation Retour de tension éclairage lampes au néon L électronique génère un retour de tension de faible intensité sur la borne 1 des...

Page 32: ...93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG Steinackerstraße 36 8902 Urdorf Zürich GB HELIOS Ventilation Systems Ltd 5 Crown Gate Wyncolls Road Severalls Industrial Park Colchester Essex CO4 9HZ Als Referenz am Gerät griffbereit aufbewahren Druckschrift Nr Please keep this manual for reference with the unit Print No Conservez cette notice à proximité de l apapreil N Réf 19053 003 06 11 w...