Installation instructions Art. No. 42207
Page 2 of 3
Status 01.2012
Installation:
Make sure that the connection values for the power supply to the movement detector agree
with the data on the rating plate for this product.
This product may only be installed by a qualified specialist electrician.
Make sure before connecting to a consumer point that the maximum load of the movement
detector is not exceeded.
The connection lines to the building must be switched free from voltage and protected against
being switch on again before the installation is done. Take the appropriate automatic circuit
breakers out of the junction box in the building.
The movement detector is equipped with 4 setting options
ON
: Permanent operation
OFF
: The movement detector is completely switched off
PIR
: The movement detector is switched on
PIR+MIC
: The movement detector and the sound sensor are switched on
Turn the time setting (TIME) completely to the left (shortest time period) and turn the
brightness switch (LUX) completely to the right (max brightness) before doing the connection
work. .
Connect the sensor to the consumer, first of all.. Continue by connecting the phase conductor
(brown) with the power supply.
You can reconnect to the power supply after completion of the installation and connection
work and after fitting the cover.
Please remember that the high sensitive device can sometimes be unintentionally activated by
sudden changes in the surroundings.
Do not install the sensor in the immediate vicinity of larger devices, such as deep freezers, air
conditioning units, sources of light, heating devices and other items.. Never set up the
movement detector on heating devices, lights, swimming pools or other reflecting surfaces.
The movement detector can be put into service after connecting to the power mains.
The rating plate must not be removed.
Test:
Set the range to maximum, the microphone to the mid range, brightness to maximum and the
time to minimum. The lamp should light up with the ON switch position. The lamp goes off with
the OFF switch position and all the functions of the movement detector are out of service.
Set the switch to PIR – the movement detector is ready for use after approx. 30 s. The lamp
starts to light up after the movement detector has received a movement signal. The lamp
switches off after approx. 10 s.
Set the switch to PIR + MIC. Cover up the sensor on the surface of the cover. The light goes
off after approx. 10 s if no further signal comes. . Clap your hands now – the light goes on
again.
Heitronic
®