13  Returning devices for repair and service 

Note: 

In  accordance  with  the  applicable  German  waste  disposal  legislation,  the  owner/client  is 

responsible for the disposal of special waste and hazardous materials. Consequently, all devices sent 
to us for repair must be free of any hazardous materials.  This also applies to possible hollow spaces 
and fissures in the devices. 
If  repair  is  necessary,  confirm  the  above-mentioned  item  in  writing 

(please  use  the  form  in  the 

Appendix)

.  If  hazardous  materials  remain  in  or  on  the  device  after  it  has  been  returned,  Heinrichs 

Messtechnik shall be authorized to remove them at the client’s expense without further inquiry. 

14  Options 

14.1  Removal and installation under process pressure 

In some cases it might be  necessary to remove  and reinstall  the  PIT sensor head for cleaning  when 
the pipe is under process pressure.  A special retraction device can be used for this purpose. 
 
When using this device, it is important to ensure that the sensor head will not be damaged by closing 
the  valve.  For  a  detailed  description  of  this  process,  see  the  Additional  Operating  Instructions  (PIT-
Druck_BA_03_eng) for removal and installation the meter under process pressure (Section 5.1.2). 

 

14.2  PIT (Sensor) Ingress protection IP68 

A special version of PIT is available with the IP 68 degree of protection. This version is equipped with 
a  special  terminal  box,  special  cable  glands  and  a  special  cable.    The  length  of  the  cable  must  be 
specified  when  placing  the  order.    The  terminal  box  does  not  need  to  be  opened  during  the 
installation. If this should be necessary, the cover must be remounted carefully.  This is the only way to 
ensure the IP 68 degree of protection.  
 

 

The standard immersion depth is 

5 m

. (Material of term. connection box Aluminum) 

 

 

Longer immersion depth up to 

25 m 

with filling of the term. Connection box with special 

sealing Compound 

„GHB1” and with factory connected cable at the sensor terminal 

connection box. (Option) 
Material of term. connection box:  Aluminum 
 

 

IP 68 version - seawater resistant: material of term. connection box : PE glass fiber reinforced, 

black 57x75x110 mm (Option)  

 

Summary of Contents for PIT Series

Page 1: ...Page 1 of 14 Magnetic Inductive Flow Velocity Sensor PIT UMF2 B Operating Manual...

Page 2: ...1 Ambient temperature ranges 7 5 3 2 Storage temperature 7 5 3 3 Climatic category 7 5 3 4 Ingress Protection 7 5 3 5 Shock resistance vibration resistance 7 5 4 Medium temperature and pressure 8 5 4...

Page 3: ...notice Unless otherwise agreed on the rejected parts must be made available to us in case a claim is made 1 Identification 1 1 Manufacturer supplier Heinrichs Messtechnik GmbH Robert Perthel Str 9 D...

Page 4: ...nd E2 at right angles to the direction of flow and the magnetic field B generated by the field coils 3 The size of this measuring circuit voltage is proportional to the mean flow velocity and thus the...

Page 5: ...he electrode cable must be shielded and protected against disturbing interferences 3 2 3 Sensor versions PIT S Wetted parts stainless steel hastelloy PTFE Transmitter neck connection flange stainless...

Page 6: ...ing to EN 29104 Measurement of Fluid Flow in Closed Conduits Methods of Evaluating the Performance of Magnetic Inductive Flow meters Based on this standard the minimum straight run of pipe ahead of th...

Page 7: ...the PIT A sensor will be supplied an earthing If the sensor does not have an earthing electrode ensure that a suitable earthing disc will be used 5 2 Use in hazardous areas The flow meters PIT UMF2 B...

Page 8: ...o 140 C 40 bar 6 Dimensions weight 6 1 PIT UMF2 B dimensional drawing for remote transmitter All dimensions in mm Weight 3 6 kg DN Nominal Diameter T Length of sensor d1 Diameter of sensor L Length of...

Page 9: ...imensions in mm Weight 5 5 kg DN Nominal Diameter T Length of sensor d1 Diameter of sensor L Length of socket weld fitting ET Immersion depth in of pipe diameter Version DN T d1 L PIT A PFA 150 600 16...

Page 10: ...flow measurements of fluids whose conductivity exceeds 20 S cm The manufacturer shall not be liable for damages that may result from unintended or inappropriate use When dealing with an aggressive med...

Page 11: ...using this device it is important to ensure that the sensor head will not be damaged by closing the valve For a detailed description of this process see the Additional Operating Instructions PIT Druc...

Page 12: ...m for remote installation The outer shield hast o be connected to the metalized cable glands at both ends The inner shields are connected to each other and are plugged into the terminal with the label...

Page 13: ...ed medium Since this measured medium is dangerous in water poisonous corrosive flammable we have checked that all hollow spaces of the device are free of these materials neutralized and flushed all ho...

Page 14: ...e 2004 108 EC Niederspannungsrichtlinie 2006 95 EG Low Voltage Directive 2006 95 EC EN 61000 6 2 2005 St rfestigkeit Industriebereich immunity industrial environment EN 61000 6 3 2007 A1 2011 St rauss...

Reviews: