Page 8 

 

ANGLE GRINDER 

-

 

When plug or switch are damaged or only have loose contact  

-

 

When  the  grinding  disc  is  rotating  unevenly  and/or  in  case  of  intense  sparking  the 
electric tool has to be repaired immediately. It must then not be operated anymore. 

 

 

Always keep the electric tool clean. The vent holes have to be kept free and there 
must net be any contaminant, as e.g. chipping in the holes. 
  

 

Do always handle the electric tool with care and caution. Avoid cuffs against the 
grinding disc. Grinding discs must never get wet nor freeze 
 

 

Do not overload the electric tool. Do only operate it within the specified range of 
capacity. 

 

6. MAINTENANCE AND REPAIR 

 

 

This electric tool is operating with a very high r.p.m. Therefore, it is necessary to 
clean the spindle bearing regularly and to replenish or change the bearing grease. 
 

 

The electric tool has to be regularly checked for correct operation and, if applicable, 
repaired. The inspection comprehends flex, wires and electric connections inside 
the  tool,  plug,  switch,  insulation,  carbon brushes,  grinding  disc,  spindle  bearing, 
moving parts, etc.  
 

 

In order to avoid accidents, the electric tool has to be disconnected from the power 
supply before any maintenance or repair takes place 
 

 

If the electric tool has been operated in a damp environment or not been used for 
a  long  time  the  insulation  resistance  between  enclosure  and  coil  has  to  be 

measured  before  using  the  tool  again.  Use  an  instrument  in  the  MΩ  range  at  a 

direct voltage of ca. 500 V for this purpose. The coil has to be dried if the insulation 
resistance is less than 7 M 

Ω. If the electric tool is damaged, it has to be repaired 

by qualified personnel.  
 

 

Unsuitable tools and improper repairs can cause injuries. The electric tool might be 
damaged.  
 

 

In this case, the manufacturer bears no responsibility for injuries or damage and 
the warranty will lapse. 

 

Summary of Contents for VPU002

Page 1: ...www heinner com VPU002 Instructions GB Instrucțiuni de utilizare RO Anleitung D Eredeti használati utasítás HU Ръководство за употреба BG Instrukcja obsługi PL ...

Page 2: ...ration 7 6 Maintenance and repair 8 1 TECHNICAL DATA Type VPU002 Grinding disc 125 mm Rated voltage 110 230V Frequency 50 60Hz Power input 900W No load revolutions per minute 12000 min Spindle M14 1 Ignition Knob 2 Drive shaft 3 Side Handle 4 Gear box 5 Cover 6 Protective cover 7 Lock button 8 Adjusting key 9 Thread 10 Inner rim ...

Page 3: ...d the apex angle must not be more than 180 and it must be neither deformed nor damaged 3 GRINDING DISC 3 1 Do only use reinforced discs with a safety limit concerning the grinding speed of not less than 80 m s They must not be used beyond their expiration date Do not use wet discs Unplug the tool before replacing the disc 3 2 Only use discs that have been certified by MPA 3 3 If you detect any dam...

Page 4: ...ght in moving parts Rubber gloves and non skid footwear are recommended when working outdoors Wear protecting hair covering to contain long hair 9 Use safety glasses 10 Connect dust extraction equipment If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used 11 Do not abuse the cord Never carry the tool by the cord or yan...

Page 5: ...hat may affect its operational A guard or other part that is damaged could be properly repaired or replaced by an authorized service center unless otherwise indicated in this instruction manual Have defective switches replaced by an authorized service facility Do not use the tool if the switch does not turn it on and off 21 Warning The use of any accessory or attachment other than those recommende...

Page 6: ... in the wheel is long enough to accept the spindle length Check that the work piece is properly supported Do not use cutting off wheel for side grinding Ensure that sparks resulting from use do not create a hazard e g do not hit persons or ignite flammable substances Ensure that ventilation openings are kept clear when working in dusty conditions If it should become necessary to clear dust first d...

Page 7: ...c tool from the power supply Then press the locking pin to block the gears Loosen the Locking nut by using the hook wrench Tighten the Locking nut after replacing the grinding disc Both carbon brushes have to be replaced at the same time when worn down to 5 mm They have to match the measures as detailed in the picture below For the best abrasive effect move the electric tool steady going with an a...

Page 8: ...lectric tool has to be regularly checked for correct operation and if applicable repaired The inspection comprehends flex wires and electric connections inside the tool plug switch insulation carbon brushes grinding disc spindle bearing moving parts etc In order to avoid accidents the electric tool has to be disconnected from the power supply before any maintenance or repair takes place If the ele...

Page 9: ...sider the following Materials and components used when manufacturing this item are high quality materials which can be reused and recycled Do not throw away the item with household waste at the end of life Take the item to a collecting point where it will be collected for free Please contact the local authorities for details on the collecting centers Conformity with the RoHS Directive the item you...