5
COMPRESSOR
Press the on / off button to turn off the
compressor. Only after doing that you may
disconnect power from source or remove the plug
from the socket.
Before working with the compressor, check the oil
level. It must be next to the round circle on the
indicator.
After using the compressor, press the on / off
button, disconnect power from source and open
the exhaust valve to reduce pressure.
Do not attempt to remove equipment parts while
it is under pressure.
Make sure that the greasing oil is clean and
available in sufficient quantity at any time.
Once connected to the power network and the
“on” button pressed, the equipment starts
automatically.
Do not inhale the air coming out from the
compressor.
Always check the pressure control valve before
starting work.
Drain the condensation from the tank in order to
avoid its corrosion.
Disconnect power from the network, remove the
plug from the socket and exhaust pressure before
starting maintenance operations.
Do not point the air stream towards your body or
other persons. No not attempt to block air with
your finger or other parts of your body.
Service
Have your electric tool repaired only by trained
personnel using only genuine spare parts.
Description of symbols
Important!
Read the instructions for use before
starting the machine!
Wear safety goggles!
Wear ear protection!
Electrocution hazard!
Hot surface!
Risk of automatic start up!
Add oil up to the middle of the red
circle!
Do not open valve before
connecting the hose.
PROPER USE
The compressor shall be used only for the
intended purpose.
Technical data
Voltage: 230 V
Frequency: 50 Hz
Power: 2 HP
Tank volume: 50 l
Air flow: 188-224 l/min
Maximum pressure: 8bar / 115 psi
Tool description
1 – handle
2 – pressure on / off button
3 – pressure controller case
4 – pressure gauge
5 – safety valve
6 – hose connector/coupler
7 – pressure regulator valve
8 – pressure gauge
9 – condensation drain adjuster
10 – wheel
11 – air tank
12 – protection cover
13 – air filter
Before starting the equipment
Make sure that the compressor location is clean,
dry and well ventilated.
To start using the compressor you must first
assembly it.
Start with the handle; in the accessory box you will
find two screws that must be inserted in the
handle tubes.
Summary of Contents for VCMP002
Page 1: ......
Page 3: ......
Page 27: ...26 Heinner e...
Page 28: ...27 2 17...
Page 29: ...28 300 o...
Page 31: ...30 7 10...
Page 32: ...31 10 500 2012 19 RoHS RoHS 2011 65...
Page 33: ...Manufactured for Network One Distribution Marcel Iancu St no 3 5 Bucharest 020757 2016...