www.heinner.com 7Kg, 220-240V~50Hz, 1200rpm
10
ELECTRICAL CONNECTION
Your washing machine is set to 220-240V and 50Hz.
The mains cord of your washing machine is equipped with a specific earthed plug.
This plug should always be inserted to a earthed socket of 10 amps.
The current value of the fuse should be 10 amps. Fuse current value of the power
line connected to this plug should also be 10 amperes.
If you don’t have such a receptacle and fuse confirming with this, please have it
done by a qualified electrician.
We do not take the responsibility of the damages that occur due to ungrounded
usage.
NOTE: Operating your machine under low voltage will cause the life cycle of your
machine to be reduced and its performance to be restricted.
WATER INLET HOSE CONNECTION
Your machine may have either a single inlet (cold) or double water inlets (cold/hot)
based on its specifications. White-capped hose should be connected to cold water inlet
and red-capped hose to hot water inlet (applicable for machines with double water
inlets).
To eliminate water leakages in points of contact, 1 or 2 nuts are provided in the hose
package (applicable for machines with double water inlets). Fit these nuts to the ends
of new water inlet hoses on the side of faucet.
Mount new water inlet hoses to a ¾ ˝, threaded faucet.
Connect the white-elbow end of the water inlet hoses to the white-filtered water inlet
valve on the rear side of the machine and the red-elbow end to red-filtered one
(applicable for machines with double water inlets). Tighten plastic parts of the
junctions using your hand. In uncertain conditions, have the connection works be done
by a qualified plumber.
Flow of water with pressure of 0,1-1 Mpa will allow your machine to operate more
efficiently.) (0,1 Mpa pressure means that more than 8 litres of water will flow through
a fully-tapped faucet per one minute.)
Ensure that points of contact do not leak by tapping the faucet completely after
carrying making the connections.
Ensure that the new water inlet hoses are not bent, broken, crushed and resized.
If your machine has double hot water inlets, the temperature of hot water inlet should
be maximum 70°C.
3/4”
Summary of Contents for HWM-V7012A++
Page 7: ...www heinner com 7Kg 220 240V 50Hz 1200rpm 6 V PRODUCT DESCRIPTION ...
Page 8: ...www heinner com 7Kg 220 240V 50Hz 1200rpm 7 ...
Page 16: ...www heinner com 7Kg 220 240V 50Hz 1200rpm 15 ...
Page 20: ...www heinner com 7Kg 220 240V 50Hz 1200rpm 19 ...
Page 50: ...www heinner com 7Kg 220 240V 50Hz 1200rpm 49 VI DESCRIEREA PRODUSULUI ...
Page 62: ...www heinner com 7Kg 220 240V 50Hz 1200rpm 61 ...