www.heinner.com 2500W, 50/60Hz, 220-240V
19
5.
ECO
When the radiator is on, press ECO button to operate in the ECO mode.
When the room temperature is below 18
℃
,
the radiator will run in the high power
setting.
When the room temperature is 18-25
℃
,
the radiator will run in a middle power
setting.
When the room temperature is above 25
℃
,
the radiator will run in the low power
setting.
Note: When the indicator temperature meets the setting temperature, the heater may
keep working for additional minutes, so that the room temperature can maintain the
setting temperature.
SAFETY FEATURES
This product has protection safeguards that turn off the product when parts become
excessively hot or if it tips over. If the product turns off, immediately unplug it from
the electrical outlet. Wait 30 minutes to allow the overheat sensors to cool off, then
plug the product back into the electrical outlet
If tipped over:
Place the product on a flat, level, stable surface in order to prevent the product from
tipping over again. The product will resume operation once it has been placed in a
safe operating position.
TIP: Always install and maintain at least one smoke detector in good operating
condition on each floor of your home. Periodically check and/or replace the battery in
your smoke detector with a new battery.
TROUBLE SHOOTING TIPS
If your heater shuts off unexpectedly or fails to operate, one of the above-mentioned
safety features may have activated to prevent overheating.
1. Unplug the unit from the electrical outlet
2. Wait for 30 minutes to allow the safety features to reset.
3. Plug the unit into the electrical outlet.
4. Turn the unit on and make sure the thermostat is set at a higher temperature than
the room temperature.