27
Ventilation of room
The air needed for burning is received from room air and the gases emitted are given
directly in room. For safe operation of your product, good room ventilation is a
precondition. If no window or room to be utilized for room ventilation is available,
additional ventilation should be installed. However, room has a door opening outside, it is
no needed to vent holes.
Room size
Ventilating opening
Smaller than 5 m³
min. 100 cm²
Between 5 m³ - 10 m³
min. 50 cm²
Bigger than 10 m³
no need
In basement or cellar
min. 65 cm²
Reduced gas flow rate setting for hob taps:
1. Ignite the burner that is to be adjustment and turn the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw. For
LPG (butane-pro pane) turn the screw clockwise. For the naturel gas, you should turn the
screw counter- clockwise once. “The normal length of a straight flame in the reduced
position should be 6-7 mm.“
4. If the flame is higher then the desired position, turn the screw clockwise.
If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced positions and
check whether the flame is on or off. Depending on the type of gas tap used in your
appliance the adjustment screw position may vary. To adjust your oven acc. To the gas type,
make the adjustement for reduced flame carefully by turning with a small screwdriver as
shown below on the screw in the middle of the gas coks as well as nozzle changes (figure 6
and 7).
Figure 6
Figure 7