MAIN FEATURE
●
●
●
●
●
HIGH RELIABILITY SENSOR
AUTO RESET AFTER ALARM
MCU PROCESSING ADOPTED
AUTO DETECT SENSOR FAILURE
INDUCED GAS- NATURAL GAS / LPG
SMT DESIGN, HIGH STABILITY
●
MANUAL FOR COMBUSTIBLE GAS DETECTOR
PRODUCT INTRODUCTION
The product is suitable for the safety of
residential house, villas, hotels, markets, boarding house etc.
The product is wall mounted gas detector with high
stability.(hereinafter called detector)
It is used for
detecting leaking gas. Advanced semiconductor sensor is
adopted to ensure high stability and long life. It is convenient
for mounting.
,
40mA(low power consumption type )
Rating Power:
3W (AC 220V supply)
Warm-up Time: about 180S
Alarm Level: 10%LEL
Sound Level:
85dB/m
Operating Temperature: -10
+50
Environment Humidity:
95
RH (no congelation)
Installation Mode: wall mounted
Alarm Output: relay output/sound & flash alarm
RF 315MHz or 433MHz (wireless type)
Radio Distance: 100m in open area (wireless type)
Outline Size
115*72*35mm
Execute Criterion
GB15322.2-2003
≤
≤
≥
℃ ~
℃
≤
%
:
:
Alarm Indicator: red LED flash
Failure Indicator: yellow LED on & beeper long- buzz
1
TECHNICAL SPECIFICATION
Operating Voltage
DC9-24V or AC100- 240V
Static Current
90mA
30mA(low power consumption type )
Alarm Current
100mA
:
: ≤
≤
:≤
PRODUCT PROFILE
INSTALLATION
1. Please confirm the induced gas is heavier than air, or lighter
than air. The gas is heavier than air: LPG etc. The gas is
lighter than air: natural gas, marsh gas and etc.
2. Choosing the suitable position to install the Detector
according to the gas specific gravity. Detecting the gas
heavier than air: Installation height from floor: 0.3-
1.0m,Semi-diameter to gas source: <1.5m;Detecting the gas
lighter than air: Installation height from ceiling: 0.3-1.0m
,Semi-diameter to gas source: <1.5m.
3. Fix the screw into the wall firmly, then hang the detector.
4. Avoid installing the detector close to the following sources
of interference: direct air flow from vents, fans, doors,
windows, sources of steam, oil vapor, etc.
5. All wires installation must accord with the National and
Local effective laws and criteria. The wires must have the
suitable size and colorful marks for avoiding connecting
error. And unsuitable connection of wires will result in the
alarm error while gas leaking happened.
Power LED(green)
Working LED
Manipulator (optional accessory )
Manipul ator
Control line
(Connect with detector)
Mechanical Arm
Rotate Axis
Fixing Part
Electromagnetism valve (optional accessory)
Manual pole
Control line (connect with detector)
Test button
DETECTOR
DIAMETER:
3M
GAS OVEN
FLOOR
CEILING
FLOO R
M312-2EVer1.0
Gas Convection Window