background image

MAIN  FEATURE

 HIGH RELIABILITY SENSOR 

 AUTO RESET AFTER ALARM 

 MCU PROCESSING  ADOPTED

 AUTO DETECT SENSOR FAILURE  

 INDUCED GAS- NATURAL GAS / LPG

 SMT DESIGN, HIGH STABILITY

 

         

MANUAL FOR COMBUSTIBLE GAS DETECTOR

PRODUCT INTRODUCTION

The  product  is  suitable  for  the  safety  of 

residential house, villas, hotels, markets, boarding house etc.

 

The  product  is  wall  mounted  gas  detector  with  high 

stability.(hereinafter  called  detector)

It  is  used  for 

detecting  leaking  gas.  Advanced  semiconductor  sensor  is 

adopted to ensure high stability and long life. It is convenient 

for  mounting. 

                 

40mA(low power consumption type  )

 Rating Power: 

3W (AC 220V supply)

Warm-up Time: about 180S

  Alarm Level: 10%LEL

  Sound Level: 

85dB/m

  Operating  Temperature: -10

 

 +50

  Environment  Humidity: 

 95

RH  (no congelation)

  Installation Mode:  wall mounted

  Alarm Output:  relay output/sound & flash alarm

                         RF 315MHz or 433MHz (wireless type)

Radio Distance:  100m in open area (wireless type)

Outline Size

115*72*35mm 

Execute  Criterion

GB15322.2-2003

℃ ~

 

  Alarm Indicator: red LED flash

  Failure  Indicator: yellow LED on & beeper long- buzz

1

TECHNICAL  SPECIFICATION

Operating  Voltage

DC9-24V or  AC100- 240V 

Static  Current

90mA

                 

30mA(low power consumption type  )

Alarm  Current

100mA

: ≤

:≤

PRODUCT PROFILE

INSTALLATION

1. Please confirm the induced gas is heavier than air, or lighter 

than  air.  The  gas  is  heavier  than  air:  LPG  etc.  The  gas  is 

lighter than air: natural gas, marsh gas and etc. 

2.  Choosing  the  suitable  position  to  install  the  Detector 

according  to  the  gas  specific  gravity.    Detecting  the  gas 

heavier  than  air:    Installation  height  from  floor:  0.3-

1.0m,Semi-diameter to gas source: <1.5m;Detecting the gas 

lighter  than  air:  Installation  height  from  ceiling:  0.3-1.0m 

,Semi-diameter to gas source: <1.5m. 

3.  Fix the  screw into the wall firmly, then hang the detector.

4. Avoid installing the detector close to the following sources 

of  interference:  direct  air  flow  from  vents,  fans,  doors, 

windows, sources of steam, oil vapor, etc. 

5.  All  wires  installation  must  accord  with  the  National  and 

Local  effective  laws  and  criteria.  The  wires  must  have  the 

suitable  size  and  colorful  marks  for  avoiding  connecting 

error. And  unsuitable  connection  of  wires  will  result  in  the 

alarm error while gas leaking happened.

Power LED(green)

Working LED

Manipulator (optional accessory )

Manipul ator

Control line

(Connect with detector)

Mechanical Arm

Rotate Axis

Fixing Part

Electromagnetism valve (optional accessory)

Manual pole

Control line (connect with detector)

Test button

DETECTOR    

DIAMETER:

3M    

GAS OVEN

FLOOR     

CEILING    

FLOO R    

M312-2EVer1.0

Gas Convection Window