Service diagnosis
28
Domestic air conditioner
Supposed
■
DC fan motor protection dues to the DC fan motor faulty
■
DC fan motor protection dues to faulty PCB
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred.
Check whether Terminal on the outdoor
mainboard is well inserted.
it is normal
Reinsert the terminals
Electrify the machine again and turn it on in
the Cool state with the remote controller.
check whether the motor could run
.
Remove fan motor after switch off
the power.
Measure the resistances
between black line(0V) and red
line( 310V),between black line(0V)
and white line(15V) of the fan
motor .
NO
YES
The resistances are
greater than 40K
Ω
NO
YES
The motor of the outdoor unit is
damaged and needs replacing.
NO
the resistances between 0V
and 310V,between 0V and 15V of
the fan terminal of outdoor pcb are
greater than 10M
Ω
.
The module pcb is
damaged, replace it
with a new one.
The
outdoor pcb
is
damaged, replace it
with a new one.
YES
The motor and
outdoor pcb are
well
YES
NO
Summary of Contents for JS035-C1
Page 12: ...Piping diagrams 10 Domestic air conditioner 5 Pinping diagrams EEV EEV ...
Page 25: ...Dimensional drawings 23 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity ...
Page 40: ...Wiring diagrams 38 Domestic air conditioner 11 Wiring diagrams 11 1 INDOOR UNIT ...
Page 41: ...Circuit diagrams 39 Domestic air conditioner 11 2 Circuit Diagrams ...
Page 42: ...Sincere Forever ...
Page 47: ...three 6 Removal Procedure 4 Domestic Air Conditioner Remove the casing 1 2 3 ...
Page 51: ...Removal Procedure 8 Domestic Air Conditioner motor cover motor cover ...
Page 52: ...Removal Procedure 9 Domestic Air Conditioner ...