![Heiko JS035-C1 Service Manual Download Page 20](http://html1.mh-extra.com/html/heiko/js035-c1/js035-c1_service-manual_2119006020.webp)
Dimensional drawings
18
Domestic air conditioner
* After the system enters the separate indoor system operation mode, the indoor system will operate
according to the set mode and neglect the communication signals of the outdoor system. However, it
has to send signals to the outdoor system.
* Quitting condition: This mode can be quitted after receiving the quitting signal from the remote
control or urgency system. The indoor system thus can quit the single operation mode.
7.1.16 Power cut compensation
* Entering condition: Press dormant button 10 times within 7 second, the buzzer will ring 4 times and
the present system status will be stored into the EEPROM of the indoor system.
* After entering the power cut compensation mode, the processing of the indoor system should be as
the followings:
Remote control urgency signal: operate according to the remote control and the urgent conditions,
the present status will be stored into the EEPROM of the indoor system.
* Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twice.
7.1.17 Time cutting function:
Connect the test program terminal on the mainboard after connecting the system to the power circuit.
The CPU of the main control will be 60 times faster.
7.2 Value of thermistor
Room sensor and Pipe Sensor
Room sensor
R25
℃
=23K
Ω
±
2%
B25
℃
/50
℃
=4200K
±
1%
R25
℃
=23K
Ω
+2%
Temp.(
℃
)
Resistor
(
K
Ω
)
Temp.
(℃)
Resistor
(
K
Ω
)
Temp.
(℃)
Resistor
(
K
Ω
)
-20
266.905
18
32.215
56
6.1
-19
250.866
19
30.671
57
5.87
-18
235.895
20
29.21
58
5.65
-17
221.911
21
27.828
59
5.44
-16
208.838
22
26.521
60
5.24
-15
196.609
23
25.283
61
5.04
-14
185.163
24
24.111
62
4.86
-13
174.443
25
23
63
4.68
-12
164.399
26
21.94
64
4.51
-11
154.983
27
20.94
65
4.35
-10
146.153
28
19.99
66
4.19
-9
137.87
29
19.09
67
4.04
-8
130.096
30
18.23
68
3.9
-7
122.799
31
17.42
69
3.76
-6
115.946
32
16.65
70
3.63
Summary of Contents for JS035-C1
Page 12: ...Piping diagrams 10 Domestic air conditioner 5 Pinping diagrams EEV EEV ...
Page 25: ...Dimensional drawings 23 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity ...
Page 40: ...Wiring diagrams 38 Domestic air conditioner 11 Wiring diagrams 11 1 INDOOR UNIT ...
Page 41: ...Circuit diagrams 39 Domestic air conditioner 11 2 Circuit Diagrams ...
Page 42: ...Sincere Forever ...
Page 47: ...three 6 Removal Procedure 4 Domestic Air Conditioner Remove the casing 1 2 3 ...
Page 51: ...Removal Procedure 8 Domestic Air Conditioner motor cover motor cover ...
Page 52: ...Removal Procedure 9 Domestic Air Conditioner ...