Manual Operation and Setup | Compensating workpiece misalignment with 3-D touch probe (option 17)
16
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2017
673
Measuring 3-D basic rotation
The misalignment of any tilted plane can be measured by probing 3
positions. The
Probe in plane
function enables you to measure this
misalignment and save it as a 3-D basic rotation in the preset table.
Operating and programming notes:
The sequence and position of the touch points
determines how the control calculates the direction
of the plane.
With the first two points you specify the direction
of the reference axis. Define the second point in the
positive direction of the desired reference axis. The
position of the third point determines the direction
of the minor axis and tool axis. Define the third
point in the positive Y axis of the desired workplace
coordinate system.
1st point is on the reference axis
2nd point is on the reference axis, in a positive
direction from the first point
3rd point is on the minor axis, in a positive
direction of the desired workpiece coordinate
system
Summary of Contents for TNC 620 E
Page 4: ......
Page 5: ...Fundamentals...
Page 34: ...Contents 34 HEIDENHAIN TNC 620 Conversational Programming User s Manual 10 2017...
Page 63: ...1 First Steps with the TNC 620...
Page 86: ......
Page 87: ...2 Introduction...
Page 123: ...3 Operating the Touchscreen...
Page 139: ...4 Fundamentals File Management...
Page 199: ...5 Programming Aids...
Page 228: ......
Page 229: ...6 Tools...
Page 271: ...7 Programming Contours...
Page 323: ...8 Data Transfer from CAD Files...
Page 344: ......
Page 345: ...9 Subprograms and Program Section Repeats...
Page 364: ......
Page 365: ...10 Programming Q Parameters...
Page 467: ...11 Miscellaneous Functions...
Page 489: ...12 Special Functions...
Page 532: ......
Page 533: ...13 Multiple Axis Machining...
Page 596: ......
Page 597: ...14 Pallet Management...
Page 610: ......
Page 611: ...15 Batch Process Manager...
Page 619: ...16 Manual Operation and Setup...
Page 693: ...17 Positioning with Manual Data Input...
Page 698: ......
Page 699: ...18 Test Run and Program Run...
Page 737: ...19 MOD Functions...
Page 774: ......
Page 775: ...20 Tables and Overviews...