![HEIDENHAIN ID 331143-03 Replacing Instructions Download Page 13](http://html1.mh-extra.com/html/heidenhain/id-331143-03/id-331143-03_replacing-instructions_2118764013.webp)
13
Note!
File the replacing instructions in the technical documentation of the machine
and record the changes!
Tests after mounting the new QSY 155 D motor
According to DIN VDE 0113, part 1 / EN 60204-1 the following must be checked after a
component has been exchanged:
1. Check whether the electrical equipment corresponds to the technical documentation.
2. Check whether the connections of the grounding conductor system are continuous.
3. Perform a functional test.
DIN VDE 0113, part 1 / EN 60204-1