![HEIDENHAIN ID 331143-03 Replacing Instructions Download Page 12](http://html1.mh-extra.com/html/heidenhain/id-331143-03/id-331143-03_replacing-instructions_2118764012.webp)
12
Further information can be found in the Technical Manual of the respective
HEIDENHAIN control.
10. When you have finished your work, create a backup of the control data with the changed entries
in the machine parameter list and the motor table.
Further information can be found in the Technical Manual of the respective
HEIDENHAIN control.
If you have any questions, contact the machine tool builder or HEIDENHAIN.
9.
Checking the machine parameters for the speed controller:
As the inertia of the new motor has been changed, it might be necessary
to optimize the speed controller.
Proceed as follows:
Do
oscillations
occur?
Optimization of the speed
controller not necessary
Yes
No
Speed controller must
be post-optimized
Traverse the axis in the Manual Operation Mode and
record I noml and v (n actl) in the integrated oscilloscope