The  Hegel H160 Integrated Amplifier is easy to connect and operate and requires no prior technical 
knowledge. However, to get the most out of the amplifier's superior sound and music quality, we have 
provided a brief description of the connections and use of the amplifier in order to provide a total music 
experience. 

GENERAL USE

On/Off

The  H160 amplifier is switched on and off with the power button, located on the bottom of the amplifier, on the left 
side, close to the front panel. When powered up, the H160 takes a few seconds to calibrate. During this time, the 
outputs are muted.

NOTE: 

When  powered up the outputs are muted and the right hand part of the display flashes for a few seconds, 

indicating mute. This is normal, and is part of the start-up procedure.

NOTE:

 When the H160 has been switched off, wait 30 seconds before powering on again.  

Display

The  left side of the display shows the selected source input, while the volume value is shown on the right side of the 
display. A flashing volume value indicates the amplifier is in mute mode.

Source Selector

The  input source selector knob is on the left side of the front panel. The three letters indicate the selected source 
input.

Volume

The  volume control knob is on the right side of the front panel. The volume level is indicated by a number between 0 
and 99 in the right side of the display, with 0 being the mute leven and 99 being max volume. The H160 powers up 
with a preset volume value. The volume level is adjusted by turning the volume knob clockwise or counter clockwise, 
or by using the Hegel remote control. 

Headphone output 

Connect the 6.3mm headphone jack to the front of the H160. This activates the headphone volume control and 
mutes speaker outputs.  

NOTE: 

Pre Out and Line Out are still active.  

Mute

Pressing  the mute button on the Hegel remote control mutes the speaker outputs and the variable line output.  The 
volume number flashes to indicate that mute is on.  Press the mute button or adjust the volume level to switch mute 
off.

Status indicators

The Hegel H160 will display the product status. 

• 

If it is connected to a network a period will light up in right hand corner of the display(after volume). 

• 

If there is a network problem, a period will start to flash after the input name in the display.

• 

If there is a firmware issue , “Err”  + error code will appear in the display.  

Summary of Contents for H160

Page 1: ...Hegel H160 High End Integrated Amplifier User manual ...

Page 2: ...ode Source Selector The input source selector knob is on the left side of the front panel The three letters indicate the selected source input Volume The volume control knob is on the right side of the front panel The volume level is indicated by a number between 0 and 99 in the right side of the display with 0 being the mute leven and 99 being max volume The H160 powers up with a preset volume va...

Page 3: ...e used to turn the display of the H160 on or off Holding the DISP button for more than 1 seconds will turn the display off while giving the button a shorter push will turn the display on Set volume for power up A user defined volume value may be used as the power up volume As a precaution the power up vol ume value is limited to a maximum level The current volume is set as the power up volume by p...

Page 4: ... input on your Hegel amplifier 14 Mute for Hegel amplifiers 15 Volume down for Hegel amplifiers The remote control uses two standard 1 5 volt LR03 AAA batteries not included To insert the bat teries please use a normal type cross head screwdriver to gently remove the four screws in the bottom of the remote control Do not use a Pozidrive cross head screwdriver it may damage the head of the screws B...

Page 5: ... the computer to the internet and close all media players such as iTunes or Windows Media Player Troubleshooting with the MAC H160 connected but no sound out of the speakers Go to System Preferences Sound Output and select TE7022 Audio w SPDIF as the Output Device 24 bit Audio The H160 can receive 24 bit music files through the USB interface Sending 24 bit audio signals from your computer may requ...

Page 6: ... com puter Launch iTunes press the AirPlay Logo and select the H160 You can also play to more than one speaker at a time select the AirPlay logo then multiple and check of the speakers that you want to listen to You can also adjust the volume on each individual speaker WARNING After selecting the H160 as the output always remember to check the iTunes volume setting before pressing play The H160 wi...

Page 7: ...e Hegel H160 Network Configuration page opens To access the setup page on a MAC open the Safari browser Under bookmarks you will find the Bon jour tab and here the Hegel H160 will appear Make sure you have included the Bonjour in the Bookmarks Menu Preferences Advanced Bon jour PLAYING FLIES ON A NETWORK DEVICE The Hegel H160 can play your media files using a UPnP compatible media player For detai...

Page 8: ...lanced XLR 1 unbalanced RCA 1 home theatre RCA Analog outputs 1 fixed line level RCA 1 variable line level RCA Digital inputs 1 coaxial S PDIF 3 optical S PDIF 1 USB 1 ethernet RJ45 Frequency response 5Hz 100kHz Signal to noise ratio More than 100dB Crosstalk Less than 100dB Distortion Less than 0 005 50W 8 Ohms 1kHz Intermodulation Less than 0 01 19kHz 20kHz Damping factor More than 1000 main pow...

Reviews: