background image

0

5

05

OPERATION NOTICE

[On regarding to keep and use conditions]
• Ensure to storage in aluminum case for avoiding high temperature, 
  High humility, even by vibration & dust.
• Take out batteries without using laser.
• Using the laser glasses at the job site/indoor where it’s a bit bright.
• Recommend to use detector at outdoor job site as if it’s more bright.
• Be assure that the switch  is “OFF” after finishing all the working.

OPERATING METHOD

• First ensure that the Switch is located at “OFF” position and insert than 
  the batteries correctly.
• Place at a proper height and level ground as may possible.
• Turning the feets to find the vial bubble at the centre position in the 
  circle.
•Switch turn “ON”, the recessed vial will become to green light and 
  horizontal line is activated. Then keep press V1/V2 button to verify by 
  checking vertical lines V1/V2 activated conditions.
• Also the down point is always following to vertical function.
• By using detector press “OUTDOOR” button.
• Don’t press “OUTDOOR” button beside using the detector.
• Replace the batteries when the green led indicator starts twinkling.
• Take out the batteries in case you don’t use the laser for a longer time.
• To get a higher or various horizontal line you can use a elevator tripod. 

Summary of Contents for EK-288P

Page 1: ...Self levelling line laser Art No L234 Manual Page 2 5 Selbstnivellierender Linienlaser Art Nr L234 Bedienungsanleitung Seite 6 9 01 01...

Page 2: ...F Use outside of this temperature range may adversely affect the accuracy of the product Dropping or impacting this product can cause malfunction inside the device Never aim the laser beam at a perso...

Page 3: ...APPLICATIONS 03 03 STANDARD ACCESSARIES...

Page 4: ...2 5 degree Wave length 635nm 2x V 635nm H 645nm Down point Damping type Magnetic Structure 360 degree turnable with fine adjustment function Power supply 3 x AA battery Alkaline Hours in continuos us...

Page 5: ...eries correctly Place at a proper height and level ground as may possible Turning the feets to find the vial bubble at the centre position in the circle Switch turn ON the recessed vial will become to...

Page 6: ...eses Temperaturbereiches wird die Genauigkeit des Ger tes beeinflusst Ein Fall oder harter Aufschlag kann zu Fehlfunktionen am Ger t f hren Zielen Sie mit dem Laser nie auf die Augen andere Personen D...

Page 7: ...07 07 LIEFERUMFANG ANWENDUNGSBEREICHE Aluminium Koffer Zieltafel G rtel Schutzbrille Batterien...

Page 8: ...ad drehbar und Feineinstellung durch Feintrieb Stromversorgung 3 x AA Alkaline Batterien Betriebsdauer ca 12 Stunden wenn alle Laser an sind Arbeitsbereich 10m Radius 50m mit Empf nger Abmessungen 200...

Page 9: ...Sie das Ger t auf eine m glichst ebenen Untergrund Sie k nnen mit Hilfe der verstellbaren F e die Libelle zentrieren Beim einschalten des Ger ts leuchtet das Libellenfenster gr n und die horizontale L...

Page 10: ...10 10...

Page 11: ...i s t d e a s s e r a b w e i s e n d m B e h l t n i s e U m f e l d e r o d e r m i t e i n e m f k e i n e n F a l l s t e d r c k e n e r h a l b d e s 11 11...

Page 12: ...12 12...