Page 1
Page 2
Page 3
Page 4
This tool emits a laser beam, which, projects a visible spot on the target
surface when the tool is used indoors.
This is a Class IIIA (U.S. version) or II (Europe version) laser tool and is
manufactured to comply with international safety rule IEC 285.
SAFETY INSTRUCTIONS:
Failure to follow warnings may result in bodily injury.
WARNINGS:
IMPORTANT:
Read all instructions prior to operating this tool and
DO NOT remove any labels from the tool.
CAUTION
– Use of controls or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
The power of the emission of the laser beam is less than 1mW in Class II
(Europe version) and is less than 5mW in Class IIIA (U.S. version), so the
following warnings must be followed to avoid injury:
DO NOT
stare directly at the laser beam.
DO NOT
project the laser beam directly into the eyes of others.
DO NOT
set up the tool at eye level or operate the tool on or near a
reflective surface, as the laser beam could be projected into your eyes or
the eyes of others.
NEED TO KNOW:
Inaccurate measurement may result from the following:
•
When the battery runs out.
•
When the measured distance is out of the specified range (2' to 50'/
0.6 to 15m).
•
When another ultrasonic source is nearby.
•
When the unit is not held perpendicularly to the target.
An error message "Err" will be displayed under the following conditions:
•
The calculation result exceeded the calculation range as specified.
•
The target surface does not provide good reflection for ultrasonic pulse
(i.e. soft and irregular surface such as thick carpet, curtain or irregular
wall paper etc)
•
The distance measured is out of specified range (>50' / 15m).
Page 7
Page 8
Page 13
Page 14
QUESTIONS?
Visit us online at:
www.strait-line.com
¿TIENE PREGUNTAS?
Visítenos en línea en la página
www.strait-line.com
QUESTIONS?
Visitez-nous sur Internet au
www.strait-line.com
OWNER’S MANUAL
DANGER
Class IIIA Laser Product
Laser radiation emitted from tool
Max. Power Output < 5mw
Wavelength: 630-670 nm
Do Not Stare Into Beam
AVOID DIRECT EYE EXPOSURE
THIS TOOL EMITS A LASER RADIATION
This caution
notice is
reminded with
a sticker
located on one
side of the unit.
LASER TAPE
ADDITION (W/O USING MEM):
• Press "Read" for measurement.
• Press "+/=" to enter the addition mode. A "+"icon will
appear on LCD.
• Press and hold "Read" again for second measurement.
• Press "+/=" again the sum is shown on the bottom.
ADDITION (USING MEM):
• Press "Mem Input" to save the desired measurement for
the addition.
• Press "Read" for new measurement.
• After getting the new measurement, press "+/=" to enter
the addition mode. A "+" icon will appear on LCD.
• Press "MEM Recall" to recall previous measurement for
the addition. The "MEM" icon will disappear and the stored
memory will be automatically cleared.
• Press "+/=" again, the sum is shown on the bottom.
LASER TAPE OPERATIONS:
• Select the measurement unit by pressing the “FT/M” button.
READ:
• Point to wall and get measured distance by pressing "Read".
• For dynamic read, press and hold "Read" key to get measured distance
displayed while the unit is moving.
• Each measurement erases the previous one.
• Measured distance is displayed on top of the LCD screen.
• Unit automatically turns itself off after 30 seconds of inactivity.
IMPORTANT NOTE:
• Make sure to point the unit perpendicular to the target.
"+" ADDITION:
• Adds measured lengths, areas and volumes together.
IMPORTANT NOTE:
• The addition between different modes
(Eg. Length plus area) will result in error. "+"
button is ignored and "Err" is shown on screen.
Previous state is restored.
Page 11
Page 12
Page 5
Page 6
Technical Specifications:
Recommended use:
Indoor
Measurement range:
2' to 50' (0.6 ~ 15 meters)
Accuracy:
±
0.5%
±
1 Digit
Resolutions:
1' (0.01m)
Aperture angle:
Approx.
±
5 degrees
Laser Diode type:
Red laser diode 650nm
Laser Class:
Class IIIa (US version) / Class II (Europe version)
Power supply:
9V block battery (not included)
Battery life:
10 hours of continuous dynamic measurement
with alkaline battery.
Dimensions:
5-1/4"/134mm x 2-5/16"/59mm x 1-5/8"/41mm
Weight:
4-1/4oz / 120g (Excluding battery)
Calculation range:
Length
- 9999'11" (9999m)
Area
- 999999 sq ft (99999m
2
)
Volume
- 999999 cu ft (99999m
3
)
Operation Environment:
Operating temperature: 32
°
F to 104
°
F (0ºC to 40ºC)
Still Air and hard target surface for accurate measurement.
IMPORTANT NOTE:
For long distance measuring (between 40' to 50' / 12m to 15m), the relative
humidity should be above 48% and target size of at least 10 ft. by 10ft /
3m by 3m.
LCD GRAPHICS:
TOOL COMPONENTS:
Laser pointer
Ultrasonic sensor
aperture
Volume computation
Area computation
Addition
Battery
compartment
2 row LCD
Memory input
Memory recall
Feet / Meter
conversion key
ON/Read key
Page 9
Page 10
MEN
INPUT
MEN
RECALL
FT/M
READ
+/=
Low Battery
Indicator
Current result
Square Feet
Cubic Feet
Square Meter
Cubic Meter
Memory
Memory /
computation
result
Addition
Area/Volume
L= Length
W= Width
H= Height
WARRANTY:
Each STRAIT-LINE
®
laser tool is warranted to be free from defects in material
and workmanship for a period of one year from the date of purchase.
During the warranty period, should the tool fail to operate under normal
conditions and be deemed defective by the manufacturer, the manufacturer
reserves the right to repair or replace the product.
This warranty does not apply to any damage resulting from, but not limited to,
the following: abuse, negligence, accident, water, being dropped from more
than 3 feet, any uses for which the tool is not designed, and/or if repairs have
been made or attempted by others. Disassembling the laser tool will also void
the warranty.
Return all parts of the broken tool to Newell Rubbermaid™
Huntersville, NC 28078-1801 USA, for a free repair or replacement if warranty
applies.
In Australia or New Zealand, return all parts of the broken tool to Newell
Rubbermaid Pty, LTD. 44-48 Rocco Drive, Scoresby Victoria 3179, Australia,
for a free repair or replacement if warranty applies.
DANGER
Class IIIA Laser Product
Laser radiation emitted from tool
Max. Power Output < 5mw
Wavelength: 630-670 nm
Do Not Stare Into Beam
AVOID DIRECT EYE EXPOSURE
THIS TOOL EMITS A LASER RADIATION
This caution
notice is
reminded
with a sticker
located on
one side of
the unit.
CARE AND HANDLING:
• The Laser Tape is a precision instrument which must be handled with care.
• Avoid shock, vibrations and extreme heat.
• Avoid dust and water, which may obstruct the lens. If needed, use a soft
cloth or cotton swab and glass cleaner to clean the lens.
• Keep the laser tool dry and clean.
• Check battery regularly to avoid deterioration.
• Remove battery if the laser tool is to be stored for
an extended period of time.
MEM INPUT:
Inserts a Length, Area or Volume into memory
*The "MEM" icon will appear.
MEM RECALL:
Displays the last stored memory .
This is either Length, Area or Volume.
The "MEM" icon will disappear and the
stored memory will be automatically cleared.
FT/M:
Change the measurement unit for Length,
Area and Volume from ft./in. to metric.
VOLUME:
• Press " " to enter Volume mode for calculation of
a room volume.
• “L” will blink showing which measurement you will be
taking. Press "Read" to take “L” measurement that is
displayed on upper portion of screen. (Step 1)
• “W” will blink showing the next measurement to take.
Press "Read" to take “W” measurement that is
displayed on upper portion of screen. (Step 2)
• “H” will blink showing the next measurement to take.
Press "Read" to take “H” measurement that displayed
on upper portion of screen. (Step 3)
• Then the Volume is automatically displayed on the
lower portion of the screen.
• Pressing the "Read" key again will toggle
back and forth between the “L”, “W” and “H”
measurements.
• To start another Volume mode, press " " key again.
• To leave the Volume mode to make a single
measurement, press and hold the "Read" key
for about 2 seconds.
MEM INPUT
MEM RECALL
FT.
M
Page 15
------------
------------
------------
AREA:
• Press " " to enter Area mode for calculation of a
room area.
• “L” will blink showing which measurement you
will be taking. Press "Read" to take “L” measurement
that is displayed on upper portion of screen. (Step 1)
• “W” will blink showing the next measurement to
take. Press "Read" to take “W” measurement that is
displayed on upper portion of screen. (Step 2)
• Then the Area is automatically displayed on the lower
portion of the screen.
• Pressing the "Read" key again will toggle back and
forth between the “L” and “W” measurements.
• To start another Area mode, press " "
key again.
• To leave the Area mode to make a single
measurement, press and hold the "Read" key for
about 2 seconds.
------------
------------
ADDITION OF AREAS UNDER AREA MODE:
• Press "Mem input" to save the calculated area.
• Press " " to measure new area (Follow step 1
& 2 under the Area section).
• After getting the desired area, press "+/=" to enter
the addition mode. A "+" icon would appear on LCD.
• Press "Mem Recall" to recall the first calculated area
for the addition. The "MEM" icon will disappear and the
stored memory will be automatically cleared.
• Press "+/=" again, the sum of both areas is shown
on bottom.
IMPORTANT NOTE:
• Before press and hold "Read" to leave the Area
mode, the measurement of "L" and "W" must be
completed first.
ADDITION OF VOLUMES UNDER VOLUME MODE:
• Press "Mem input" to save to the calculated volume.
• Press " " to measure new volume (Follow
step 1 to 3 under the Volume section).
• After getting the calculated volume, press "+/=" to enter
the addition mode. A "+" icon would appear on
LCD.
• Press "Mem Recall" to recall the first calculated volume
for the addition. The "MEM" icon will disappear and the
stored memory will be automatically cleared.
• Press "+/=" again, the sum of both volumes is shown
on bottom.
IMPORTANT NOTE:
• Before press and hold "Read" to leave the Volume
mode, the measurement of "L", "W" and "H" must
be completed first.
POWER SUPPLY:
The Laser Tape requires one 9 volt battery to operate (not included)
BATTERY INSTALLATION:
• Open battery compartment door on the back of the unit.
• Plug one 9 volt block battery onto the battery connector.
• Close battery compartment door.
IMPORTANT NOTE:
• When battery is low, the low battery icon will be continuously
displayed on the LCD.
HOW TO USE YOUR STRAIT-LINE LASER TAPE
• Position and point the unit perpendicular to the target.
The laser pointer will show where the tool is pointing and is only on while a
reading is being taken.
• The target must be a hard regular surface unincumbered by objects / obstacles
in the measurement field.
• For more accurate result, choose a target that is flat and large with hard
surfaces.
• Put a piece of cardboard in front of the target if the measured target is small,
irregular or soft.
• This tool cannot measure through glass even though the laser beam can
pass through.
Caution: Do not stare into Laser beam. Hold tool with beam above or
below eye level.
Model: SW-104K (Laser Tape)
Date: June 25,03
G03368
©2003
Huntersville, NC 28078-1801 USA
1-800-464-7946
85-104-K01-001