background image

Page 1

Page 2

Page 3

Page 4

This tool emits a laser beam, which, projects a visible spot on the target 
surface when the tool is used indoors.  

This is a Class IIIA (U.S. version) or II (Europe version) laser tool and is 
manufactured to comply with international safety rule IEC 285.

SAFETY INSTRUCTIONS:  

Failure to follow warnings may result in bodily injury.

WARNINGS:  

IMPORTANT:  

Read all instructions prior to operating this tool and 

DO NOT remove any labels from the tool.

CAUTION 

– Use of controls or performance of procedures other than 

those specified herein may result in hazardous radiation exposure.

The power of the emission of the laser beam is less than 1mW in Class II 

(Europe version) and is less than 5mW in Class IIIA (U.S. version), so the 

following warnings must be followed to avoid injury:

DO NOT 

stare directly at the laser beam.

DO NOT

 project the laser beam directly into the eyes of others.

DO NOT 

set up the tool at eye level or operate the tool on or near a 

reflective surface, as the laser beam could be projected into your eyes or 

the eyes of others.

NEED TO KNOW:

Inaccurate measurement may result from the following:

When the battery runs out.

When the measured distance is out of the specified range (2' to 50'/ 

0.6 to 15m).

When another ultrasonic source is nearby.

When the unit is not held perpendicularly to the target.

An error message "Err" will be displayed under the following conditions:

The calculation result exceeded the calculation range as specified.

The target surface does not provide good reflection for ultrasonic pulse 

(i.e. soft and irregular surface such as thick carpet, curtain or irregular 

wall paper etc)

The distance measured is out of specified range (>50' / 15m).

Page 7

Page 8

Page 13

Page 14

QUESTIONS? 

Visit us online at: 

www.strait-line.com

¿TIENE PREGUNTAS?  

Visítenos en línea en la página 

www.strait-line.com

QUESTIONS? 
Visitez-nous sur Internet au 

www.strait-line.com

OWNER’S MANUAL

DANGER 

Class IIIA Laser Product

Laser radiation emitted from tool

Max. Power Output < 5mw

Wavelength: 630-670 nm

Do Not Stare Into Beam

AVOID DIRECT EYE EXPOSURE

THIS TOOL EMITS A LASER RADIATION

This caution 

notice is 

reminded with 

a sticker 

located on one 
side of the unit.

LASER TAPE

ADDITION (W/O USING MEM): 

• Press "Read" for measurement.
• Press "+/=" to enter the addition mode. A "+"icon will 

appear on LCD.

• Press and hold "Read" again for second measurement.
• Press "+/=" again the sum is shown on the bottom.

ADDITION (USING MEM):

• Press "Mem Input" to save the desired measurement for 

the addition.

• Press "Read" for new measurement.
• After getting the new measurement, press "+/=" to enter 

the addition mode. A "+" icon will appear on LCD.

• Press "MEM Recall" to recall previous measurement for 

the addition. The "MEM" icon will disappear and the stored 
memory will be automatically cleared.

• Press "+/=" again, the sum is shown on the bottom.

LASER TAPE OPERATIONS:

• Select the measurement unit by pressing the “FT/M” button.

READ:

• Point to wall and get measured distance by pressing "Read".
• For dynamic read, press and hold "Read" key to get measured distance 

displayed while the unit is moving.

• Each measurement erases the previous one.
• Measured distance is displayed on top of the LCD screen.
• Unit automatically turns itself off after 30 seconds of inactivity.

IMPORTANT NOTE:

• Make sure to point the unit perpendicular to the target.

"+" ADDITION:

• Adds measured lengths, areas and volumes together.

IMPORTANT NOTE:

• The addition between different modes 

(Eg. Length plus area) will result in error. "+" 

button is ignored and "Err" is shown on screen. 

Previous state is restored.

Page 11

Page 12

Page 5

Page 6

Technical Specifications:

Recommended use: 

Indoor

Measurement range: 

2' to 50' (0.6 ~ 15 meters)

Accuracy: 

±

0.5% 

±

 1 Digit

Resolutions: 

1' (0.01m)

Aperture angle: 

Approx. 

±

5 degrees

Laser Diode type: 

Red laser diode 650nm

Laser Class: 

Class IIIa (US version) / Class II (Europe version)

Power supply: 

9V block battery (not included)

Battery life: 

10 hours of continuous dynamic measurement 

with alkaline battery.

Dimensions: 

5-1/4"/134mm x 2-5/16"/59mm x 1-5/8"/41mm

Weight: 

4-1/4oz / 120g (Excluding battery)

 

Calculation range:

Length 

- 9999'11" (9999m)

Area 

- 999999 sq ft (99999m

2

)

Volume 

- 999999 cu ft (99999m

3

)

 

Operation Environment:

Operating temperature:  32

°

F to 104

°

F (0ºC to 40ºC)

Still Air and hard target surface for accurate measurement.

 

IMPORTANT NOTE:

For long distance measuring (between 40' to 50' / 12m to 15m), the relative 

humidity should be above 48% and target size of at least 10 ft. by 10ft / 

3m by 3m.

LCD GRAPHICS:

TOOL COMPONENTS:

Laser pointer

Ultrasonic sensor
aperture

Volume computation
Area computation
Addition

Battery
compartment

2 row LCD 

Memory input
Memory recall
Feet / Meter
conversion key

ON/Read key

Page 9

Page 10

MEN 

INPUT

MEN 

RECALL

FT/M

READ

+/=

Low Battery 

Indicator

Current result

Square Feet
Cubic Feet
Square Meter
Cubic Meter

Memory

Memory /

computation

result

Addition

Area/Volume

L= Length
W= Width
H= Height

WARRANTY: 

Each STRAIT-LINE

®

 laser tool is warranted to be free from defects in material 

and workmanship for a period of one year from the date of purchase.  
During the warranty period, should the tool fail to operate under normal 
conditions and be deemed defective by the manufacturer, the manufacturer 
reserves the right to repair or replace the product. 

This warranty does not apply to any damage resulting from, but not limited to, 
the following: abuse, negligence, accident, water, being dropped from more 
than 3 feet, any uses for which the tool is not designed, and/or if repairs have 
been made or attempted by others. Disassembling the laser tool will also void 
the warranty.

Return all parts of the broken tool to Newell Rubbermaid™ 
Huntersville, NC 28078-1801 USA, for a free repair or replacement if warranty 
applies.

In Australia or New Zealand, return all parts of the broken tool to Newell 
Rubbermaid Pty, LTD. 44-48 Rocco Drive, Scoresby Victoria 3179, Australia, 
for a free repair or replacement if warranty applies.

DANGER 

Class IIIA Laser Product

Laser radiation emitted from tool

Max. Power Output < 5mw

Wavelength: 630-670 nm

Do Not Stare Into Beam

AVOID DIRECT EYE EXPOSURE

THIS TOOL EMITS A LASER RADIATION

This caution 

notice is 

reminded 

with a sticker 

located on 

one side of 

the unit.

CARE AND HANDLING:

• The Laser Tape is a precision instrument which must be handled with care.
• Avoid shock, vibrations and extreme heat.
• Avoid dust and water, which may obstruct the lens. If needed, use a soft
 cloth or cotton swab and glass cleaner to clean the lens.
• Keep the laser tool dry and clean.
• Check battery regularly to avoid deterioration.
• Remove battery if the laser tool is to be stored for 

an extended period of time.

MEM INPUT:

Inserts a Length, Area or Volume into memory

*The "MEM" icon will appear.

MEM RECALL:

Displays the last stored memory .  

This is either Length, Area or Volume.

The "MEM" icon will disappear and the

stored memory will be automatically cleared.

FT/M:

Change the measurement unit for Length, 

Area and Volume from ft./in. to metric.

VOLUME:

• Press "         " to enter Volume mode for calculation of

a room volume.

• “L” will blink showing which measurement you will be 

taking. Press "Read" to take “L” measurement that is 
displayed on upper portion of screen. (Step 1)

• “W” will blink showing the next measurement to take.  

Press "Read" to take “W” measurement that is 
displayed on upper portion of screen. (Step 2)

• “H” will blink showing the next measurement to take.  

Press "Read" to take “H” measurement that displayed 
on upper portion of screen. (Step 3)

• Then the Volume is automatically displayed on the 

lower portion of the screen.

• Pressing the "Read" key again will toggle 

back and forth between the “L”, “W” and “H” 
measurements.

• To start another Volume mode, press "         " key again.
• To leave the Volume mode to make a single 

measurement, press and hold the "Read" key
for about 2 seconds.

MEM INPUT

MEM RECALL

FT.

M

Page 15

------------

------------

------------

AREA:

• Press "        " to enter Area mode for calculation of a 

room area.

• “L” will blink showing which measurement you 

will be taking. Press "Read" to take “L” measurement 
that is displayed on upper portion of screen. (Step 1)

• “W” will blink showing the next measurement to 

take.  Press "Read" to take “W” measurement that is 
displayed on upper portion of screen. (Step 2)

• Then the Area is automatically displayed on the lower 

portion of the screen.

• Pressing the "Read" key again will toggle back and 

forth between the “L” and “W” measurements.

• To start another Area mode, press "        " 

key again.

• To leave the Area mode to make a single 

measurement, press and hold the "Read" key for 
about 2 seconds.

------------

------------

ADDITION OF AREAS UNDER AREA MODE:

• Press "Mem input" to save the calculated area.
• Press "        " to measure new area (Follow step 1 

& 2 under the Area section).

• After getting the desired area, press "+/=" to enter

the addition mode. A "+" icon would appear on LCD.

• Press "Mem Recall" to recall the first calculated area 

for the addition. The "MEM" icon will disappear and the
stored memory will be automatically cleared.

• Press "+/=" again, the sum of both areas is shown 

on bottom.

IMPORTANT NOTE:
• Before press and hold "Read" to leave the Area 

mode, the measurement of "L" and "W" must be
completed first.

ADDITION OF VOLUMES UNDER VOLUME MODE:

• Press "Mem input" to save to the calculated volume.
• Press "         " to measure new volume (Follow  

step 1 to 3 under the Volume section).

• After getting the calculated volume, press "+/=" to enter

the addition mode. A "+" icon would appear on
LCD.

• Press "Mem Recall" to recall the first calculated volume

 for the addition. The "MEM" icon will disappear and the
stored memory will be automatically cleared.

• Press "+/=" again, the sum of both volumes is shown 

on bottom.

IMPORTANT NOTE:
• Before press and hold "Read" to leave the Volume

mode, the measurement of "L", "W" and "H" must 
be completed first.

POWER SUPPLY:

The Laser Tape requires one 9 volt battery to operate (not included)

 

BATTERY INSTALLATION:

• Open battery compartment door on the back of the unit.
• Plug one 9 volt block battery onto the battery connector.
• Close battery compartment door. 

 

IMPORTANT NOTE:

• When battery is low, the low battery icon will be continuously 

displayed on the LCD.

 

HOW TO USE YOUR STRAIT-LINE LASER TAPE

• Position and point the unit perpendicular to the target.
   The laser pointer will show where the tool is pointing and is only on while a 

reading is being taken.

• The target must be a hard regular surface unincumbered by objects / obstacles

in the measurement field.

• For more accurate result, choose a target that is flat and large with hard

surfaces.

• Put a piece of cardboard in front of the target if the measured target is small,

irregular or soft.

• This tool cannot measure through glass even though the laser beam can

pass through.

 

Caution: Do not stare into Laser beam. Hold tool with beam above or 

below eye level.

 

 

Model: SW-104K (Laser Tape)

Date: June 25,03

G03368

©2003

Huntersville, NC 28078-1801 USA

                              1-800-464-7946

85-104-K01-001

Reviews: