ACCESSORIES

Please notice our extensive range of reflectors, umbrellas, softboxes, stands and other accessories.
Visit us on

www.hedler.com

HEDLER WARRANTY

All Hedler equipment is fully guaranteed against any material or manufacturing defects for three years after date of purchase. Parts made out of 
glass, fuses, halogen bulbs, flash tubes, Pyrex

®

 coverings and single cell LED modules are not covered by this warranty.

MAINTENANCE and REPAIR

For a secure operation of light units they have to be maintained. Therefore: before using light units they have to be checked visually and an 
electrical safety check has to be done every twelve month. The results of this check have to be documented and archived. If you have any 
questions about the safety check, please fell free to contact us.
0049(0)6482-918100
www.hedler.com

If repair is required, please, contact your dealer, the authorized distributor in your country or the Hedler factory directly. Please note, that a 
pre-dismantled light unit could cause increased repair costs.

CHECK

All HEDLER light units are tested at HEDLER Systemlicht GmbH according to DIN 0701/0702 with protocol I. This check has to be repeated 
yearly. Please contact us.

0049(0)6482-918100
www.hedler.com

PLEASE NOTE - SPECIAL SET-UP ADVICE

Light units of the HEDLER DX- and DF-range have an up side and an underside, setting-up the light unit it is important to take care of the correct 
position of these sides. The light unit(s) is/are set-up correctly, if the QuickFit Adapter (located at the front side of the housing) is located beneath 
the bulb respectively the safety glass (as shown on the photograph) or the Fresnel lens.

To ensure a continuous operation, the light units of the HEDLER DX- and DF-range have to be set-up / operated in the position described 
respectively as shown on the photograph.

If you take the light unit in operation in an upside-down set-up, the internal automatic temperature safety switch will (according to the ambient 
conditions) switch off the light unit after some operation time until it has cooled down. This is not a failure or a maloperation of the light unit(s) 
of the HEDLER DX- and DF-range, it is a protection shutoff for the internal electronic ballast to prevent overheating.

Set-up correctly - shown for the HEDLER DX15.

H E D L E R   S y s t e m l i c h t   G m b H       H e e r s t r a s s e   1 1 2       D - 6 5 5 9 4   R u n k e l   /   L a h n       w w w . h e d l e r. c o m
Te l e f o n   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 0 0       Te l e f a x   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 1 1       e M a i l   i n f o @ h e d l e r. c o m

Daylight DX15 / DF 15

HEDLER

®

S y s t e m l i c h t

OPERATION MANUAL

Summary of Contents for Daylight DX15

Page 1: ...e QuickFit adapter for attaching all of the HEDLER lightformers quickly and easily Interchangeable reflectors with bayonet ring can be attached in the following way place the rim of the ring into the...

Page 2: ...nce Position Under any circumstances do not under run the safety Tilt light unit max clearances given within the graphic to inflammable material 45 upwards down wards in operation HEDLER S y s t e m l...

Page 3: ...the socket wrench which was delivered with the DF15 After loosening the socket screw completely remove the cover plate guard Turn the focusing knob until the DF15 has its maximum spot light position P...

Page 4: ...6482 918100 www hedler com PLEASE NOTE SPECIAL SET UP ADVICE Light units of the HEDLER DX and DF range have an up side and an underside setting up the light unit it is important to take care of the co...

Page 5: ...nit s in hospital s museum s factory factories asf with permission of the appropriate responsible public authority administration company management or business management only If not taking care of t...

Page 6: ...use a Hedler light unit with a defective safety glass a defective Pyrex cover a defective flash bulb defective bulb s and or defective fuse s Never put a Hedler light unit into operation with a defec...

Page 7: ...flectors parts of softboxes and reflex umbrellas and some accessories completely after using them and before packing them away not doing so can cause serious burnig and or the risk of sparking Not use...